Bleeding coolant circuit
- The steps for removing the air conditioner components described in this Workshop Manual ensure that only a small quantity of air enters the coolant circuit. Therefore it is not necessary to completely bleed the coolant circuit after removing and installing these components.
- If, however, a large quantity of coolant has escaped on account of some other problem, e.g. a leaking hose, bleed the coolant circuit completely using the cooling system charge unit VAS 6096Rep. gr.19Cooling system/coolant; draining and adding coolant.
- After bleeding and filling the coolant circuit with the cooling system charge unit VAS 6096, the part of the air conditioner coolant circuit concerned (heat exchanger and corresponding tubing) may have to be bled again via the vent hole (arrow).

- As, on installing the heating system heat exchanger in the air conditioning unit, the coolant circulation pump V50 and the coolant shut-off valve N82 for example, only a small quantity of air ingresses into the coolant circuit and this is pre-filled again when the components are installed, there is very little air in the coolant circuit. With the engine warm, it is therefore sufficient to set the air conditioner to maximum heat output (to actuate the coolant circulation pump V50) and to run the engine for a few minutes at high idle (approx. 2000 rpm) to completely bleed the coolant circuit.
- When bleeding the coolant circuit, take special care to ensure complete bleeding of the heat exchanger. If air bubbles remain in the heat exchanger, complaints may be received about a lack of heat output in winter or differences in the temperature of the air flowing out of the vents with the same setting in control mode → Chapter.

Attach the pipe V.A.G 1274/10 to the adapter V.A.G 1274/8.
Add coolant until the pipe for the cooling system tester is full. If necessary, top up during the bleeding procedure Rep. gr.19Cooling system/coolant; Draining and filling cooling system
Start the engine and let it run until operating temperature is attained.
Set the operating unit, Climatronic control unit J255 to maximum heat output (e.g. “HI” temperature setting) for the driver and front passenger sides.
Set the fresh air blower speed to approx. 30 % of maximum output.
The fresh air blower runs at a speed in the lower output range.Switch on for approx. 30 seconds on vehicles with auxiliary heater.
Run the engine for 2 minutes at 2000 rpm.
Shut off the engine and allow to cool down.
Check the coolant level.