Removing and installing receiver
- Make
- Audi
- Model
- A6 C7
- Year
- 2011–2018
- Section
- Refrigerant circuit › Removing and installing receiver
Removing and installing receiver
Note
- Depending on the version of the condenser, the receiver may be attached to or integrated into the condenser. Renew dryer cartridge (for condenser with integrated receiver) → Chapter.

Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Remove the lock carrier cover General body repairs, exteriorRep. gr.63Front bumper; Removing and installing add-on components.
If fitted, remove bolts (arrows).
Detach air duct (1).
Remove bolts (arrows).

Detach air duct (1) at intermediate flange (2) for air cleaner housing.
On vehicles without charge air cooler, remove the bumper cover locking element General body repairs, exteriorRep. gr.63Front bumper; Removing and installing add-on components.
Remove the charge air cooler Rep. gr.21Charge air system; Removing and installing charge air cooler.
Push up protective collar (B) at connection point.

Remove bolts (A).
Unscrew bolt (C) and lift off bracket (D).
Pull receiver (F) upwards out of condenser (E)(arrow).
Note
- Make sure that the rubber grommet (B) is not lost when detaching the receiver.
- Seal the open connections at the receiver and condenser with suitable caps (to prevent the ingress of dirt and moisture).
Install in reverse order of removal; note the following:
Renew O-rings; for correct version, refer to Electronic parts catalogue.
Clean contact surface of condenser (C).

Check connections at condenser and receiver for damage.
Insert O-rings (D and E) in grooves (arrows) in corresponding connections.
Note
- Coat O-rings lightly with refrigerant oil before fitting → Chapter.
- Check refrigerant pipes to evaporator for contamination and damage.
- Make sure O-rings are seated correctly in groove (arrow) of corresponding connection.
Position receiver (B) on condenser and tighten bolts.
- Receiver to condenser: 10 Nm
Fit protective collar (A) over connection point.
Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Starting up air conditioner after charging refrigerant circuit Chapter and Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner.
As a final step, interrogate event memory and erase any entries displayed Vehicle diagnostic tester (“Guided Fault Finding”).
Parts & tools for this job For 2011 Audi A6
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A6 2011 cabin filter