audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Pressure, Vacuum and Temperature Specifications|Page 18566 > < Pressure, Vacuum and Temperature Specifications|Page 18564
Page 2
background image

-

Since November 1997, restrictors with a smaller hole have been installed in production, and are colored (at first yellow) so that they can be
identified.

-

On vehicles in which the colored restrictors are installed, somewhat more refrigerant has to be added.

 
Capacities for the Audi A6

NOTES
-

The AudiA6 A/C refrigerant system can be identified by the restrictor reservoir and compressor from the manufacturer "Denso."

-

There was a running change in production from the version 1 air conditioner to the version 2 air conditioner starting September 1998. Since the
evaporator was also modified along with the air conditioner the capacity could be reduced. The two air conditioner versions can be differentiated
by specific characteristics. See: Application and ID 

-

During a running change in production starting January 1999, a condenser with smaller flat tubes is installed. After the parts are used up, only
condensers with small flat tubes will be available from the Parts Department. Because of the smaller internal volume of the new condenser the
capacity is lower. Take measurements to differentiate between the two versions of the condensers.. The new capacities for the condensers with the
smaller flat tubes will be available at a later time. 

-

If the condenser is replaced, attention must be paid to the dimensions of the flat tubes. If a condenser with other dimensions is installed, the
information plate with the capacity data for the refrigerant must also be replaced, or the old capacity data has to be removed and the new capacity
entered using a waterproof pen.

-

Since November 1997, restrictors with a modified hole (colored) have been installed in production. For vehicles in which modified restrictors are
installed, the capacities are increased by 50 grams. If a restrictor with a different hole is installed, the information plate with the capacity data for
the refrigerant must also be replaced, or the old capacity data has to be removed and the new capacity entered using a waterproof pen.

-

So that the two restrictor versions can be differentiated, the restrictor with the smaller hole (narrow neck) is colored (at first yellow).

-

If a colored restrictor is installed in a vehicle in which the previous restrictor had not been colored, 50 grams more refrigerant should be added.

-

The compressor manufacturer "Nippondenso" has changed its name to "Denso."

Pressure, Vacuum and Temperature Specifications|Page 18566 > < Pressure, Vacuum and Temperature Specifications|Page 18564