Removing and installing desiccant bag/desiccant cartridge
- Make
- Audi
- Model
- A7 Sportback
- Year
- 2010–2018
- Section
- Refrigerant circuit › Removing and installing desiccant bag/desiccant cartridge
Removing and installing desiccant bag/desiccant cartridge
Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
Extract the refrigerant and then immediately open up the refrigerant circuit.Extract the refrigerant again if more than 10 minutes have passed since the initial extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit.
Note
- Specific tools are required when discharging the refrigerant circuit, and this work may only be performed by qualified personnel Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
- There are different versions of the condenser and the integrated dryer cartridge. For correct version refer to Electronic parts catalogue.
Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
On vehicles without charge air cooler, remove the lock carrier cover locking element General body repairs, exteriorRep. gr.63Front bumper; Removing and installing add-on components.
Remove the charge air cooler Rep. gr.21Charge air system; Removing and installing charge air cooler.
Use the pressure gauge of an air conditioner service station to check the pressure in the refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.

Warning Danger from escaping pressurised refrigerant.
Frostbite on skin and other parts of the body.
- Only remove the plug when the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure.
Unscrew plug (A).
Using long-nose pliers, pull dryer cartridge (D) out of receiver (E).
Install in reverse order of removal; note the following:
- Chapter“Exploded view - condenser, desiccant cartridge”
Note
- The plug, O-ring and dryer cartridge must always be renewed after the receiver has been opened Electronic parts catalogue.
Check threads and sealing surfaces of receiver at condenser for contamination or damage via opening.
Note
- Keep bag with air-tight seal containing dryer cartridge closed as long as possible. Only open bag immediately before inserting dryer cartridge in condenser. After opening bag, dryer cartridge soon becomes saturated with moisture from ambient air and becomes unusable.
- Coat O-ring of plug with refrigerant oil before fitting → Chapter.
Take desiccant cartridge (D) out of its bag and insert it in receiver (E) of condenser.

Fit and screw in the screw plug (A).
Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Start up air conditioner after charging refrigerant circuit → Chapter.
As a final step, interrogate event memory and erase any entries displayed Vehicle diagnostic tester (“Guided Fault Finding”).