Checking activation
- Make
- Audi
- Model
- A8 D2
- Year
- 1994–2002
- Section
- Servicing exhaust flap › Checking activation
Checking activation
Vehicle diagnostic, testing and information system VAS 5051 with diagnosis lead VAS 5051/1 is connected; vehicle self-diagnosis and vehicle system “01 - Engine electronics” is selected. When doing this the ignition must be switched on.Connect voltage tester V.A.G 1527 B between contacts (1) and (2).

Under selection menu (1) select the diagnostic function “03 - Final control diagnosis”.

Press the button → until the exhaust flap valve N321 is actuated.
LED should flash slowly.Note
- Voltage testers with a low current draw do not go out completely between activation signals from engine control unit, but continue to glow slightly and become distinctly brighter on activation.
Exit function “03 - Final control diagnosis” by pressing the ← key.
Press the diagnostic function “06 - end output” and switch off the ignition.
If the LED does not flash:
Connect test box V.A.G 1598/31 to connectors of wiring harness with black covering for engine control unit J623 (in electronics box, left-side); the engine control unit should not be connected. Connect earth clip of test box to earth Motronic injection and ignition system (12-cyl.)Rep. Gr.24.

Warning To prevent damage to electronic components, select appropriate measuring range before connecting measuring leads and observe test requirements.
Check for open circuit in the following wiring connections:

| Connector Contact | Test box V.A.G 1598/31 Socket |
|---|---|
| (1) | 45 |
| (2) | 1 or 2 |
If necessary repair wiring connection.