Connect voltage tester V.A.G 1527 B as follows:

| Solenoid valve for camshaft adjustment | Connector Contact |
|---|---|
| Inlet bank 1 N205 | 1 + 2 |
| Inlet bank 2 N208 | 1 + 2 |
| Exhaust bank 1 N318 | 2 + 3 |
| Exhaust bank 2 N319 | 2 + 3 |

Under selection menu (1) select the diagnostic function “03 - Final control diagnosis”.
Press the button → until the relevant camshaft control valve is actuated.
The LED should flash.If the LED lamp does not flash or lights up continuously:

Connect test box V.A.G 1598/31 to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth Motronic injection and ignition system (6-cyl.)Rep. Gr.24.
Check for open circuit and short to positive or earth in the following wiring:

| Solenoid valve for camshaft adjustment | Connector Contact | Test box V.A.G 1598/31 Socket |
|---|---|---|
| Inlet bank 1 N205 | 1 | 115 |
| Inlet bank 2 N208 | 1 | 120 |
| Exhaust bank 1 N318 | 1 | 22 |
| Exhaust bank 2 N319 | 1 | 18 |
If necessary repair wiring connection.
If the wiring is OK:
Renew engine control unit.
If no fault is found:
Renew the mechanical camshaft adjuster; see Removing and installing camshafts and camshaft adjuster → Chapter.