Checking cooling output
- Make
- Audi
- Model
- A8 D3
- Year
- 2002–2010
- Section
- Checking cooling output of air conditioner › Checking cooling output
Checking cooling output
Prerequisites for checking cooling output satisfied → Chapter
Measure the ambient temperature (must be above 15 °C).
Close the doors, front lid, windows and sun roof.
Open all dash panel vents.
Switch on ignition.
Set „Econ“ mode on MMi (A/C mode off).
Close the vents in the „B“ pillar.
Set the handwheel for the variable temperature centre vent to „Warm“.
Start the engine.
Start air conditioner guided fault-finding "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
In the „Reading measured value block“ function, select the display group with the following values (actuation of the air conditioner compressor regulating valve N280 and measured value of the high-pressure sender G65) and check the display "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- Actuation of the compressor via the air conditioner compressor regulating valve N280 deactivated (compressor switched off, display in display zone 0%)
- Pressure in refrigerant circuit transmitted by the high-pressure sender G65 equal to or greater than the value in the table at the measured ambient temperature
| Ambient temperature in °C | Displayed pressure (in bar absolute) |
|---|---|
| 15 | 4,7 |
| 20 | 5,6 |
| 25 | 6,6 |
| 30 | 7,6 |
| 35 | 8,8 |
Note
- At absolute pressure, 0 bar corresponds to an absolute vacuum. Normal ambient pressure thus corresponds to roughly 1 bar absolute. On the scales of most pressure gauges, 0 bar corresponds to an absolute pressure of one bar (can be seen from -1 mark below 0).
- The pressure in the refrigerant circuit is governed by the ambient temperature. Due to the radiation of heat by components (e.g. the radiator fan), the pressure displayed with a warm engine is slightly higher than that given for the corresponding ambient temperature.
If the displayed pressure in the refrigerant circuit is lower than that given in the table:
Check the signal of the air conditioner high-pressure sender G65Chapter.
If no fault is found at the air conditioner high-pressure sender G65, there is not enough refrigerant in the circuit. Take the vehicle to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a.
If the pressure in the refrigerant circuit is OK:
Switch on the compressor by selecting „Auto“ mode on the front operating and display unit, Climatronic control unit J255 or on the MMI (Multi Media Interface).
Select „Lo“ temperature (for driver and front passenger side) on the front operating and display unit, Climatronic control unit J255.
Set the air outflow direction on the front operating and display unit, Climatronic control unit J255 to „dash panel vents“.
Select the „Reading measured value block“ function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Check the diagnosis tester display in the various display zones:
The display zone for actuation of the air conditioner compressor regulating valve N280 shows a duty cycle greater than 30% ( N280 actuated, compressor switched on).
The display zone for the current to the air conditioner compressor regulating valve N280 shows a current greater than 0.3 A (current flowing via N280, compressor switched on).
The pressure measured by the high-pressure sender G65 and displayed increases above the value with the compressor switched off.
Note
- The air conditioner compressor regulating valve N280 is actuated by the front operating and display unit, Climatronic control unit J255 such that the temperature of the air downstream of the evaporator reaches the specified value (approx. 2 to 5 °C):
- After starting the vehicle, a value greater than 75 % (0.55A) is displayed depending on the measured temperature, engine speed and electrical system voltage.
- As soon as the temperature measured by the evaporator output temperature sender G263 approaches the specified value, actuation is cancelled and the compressor output thus reduced.
- The connectors to the air conditioner compressor regulating valve N280 and the electric engine mounting are identical. If the connectors are interchanged (possible for example on vehicles with 4.2 l engine), no entry is made in the fault memory, but the compressor is constantly actuated and the evaporator may ice up.
- If no or an insufficient current is displayed in the display zone with the values for actuation of the air conditioner compressor regulating valve N280, check actuation of N280Chapter.
- If the pressure indicated in the display zone with the measured value of the high-pressure sender G65 does not change and actuation of the compressor is OK, check whether the air conditioner compressor regulating valve N280 is actually being actuated and the compressor actually being driven (an overload safeguard is fitted between the compressor and the pulley/drive unit; the compressor is not driven if this has been tripped). If no fault can be found, there is a problem with the refrigerant circuit. The vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a (inform the workshop of the problem).
Press the air recirculation mode button on the front operating and display unit, Climatronic control unit J255 (symbol for „air recirculation mode“ in button lights).
Set the engine speed to 2000 rpm (start of time measurement).
In the „Reading measured value block“ function, select the display group with the measured value of the evaporator output temperature sender G263"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Compare the measured value indicated in the display zone (for the evaporator output temperature sender G263) to the values in the graph.

Depending on the ambient temperature, the measured air temperature must be within the stated tolerance range after 5 minutes.
- If the required values are not attained, check the measured value of the evaporator output temperature sender G263 and compare the measured values displayed for the evaporator output temperature sender G263 to the measured values for the left vent temperature sender G150 and right vent temperature sender G151:
If the measured values for the left vent temperature sender G150 and the right vent temperature sender G151 only deviiate slightly from the measured value for the evaporator output temperature sender G263: Perform the measures to be taken if the readout does not match the specification → Chapter.
If the measured value of the evaporator output temperature sender G263 is higher than that of the left vent temperature sender G150 and the right vent temperature sender G151, check proper installation of the evaporator output temperature sender G263 and perform the electrical check for this sender → Chapter and "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Note
- Operation of the air conditioner is apparent, for example, from the fact that the refrigerant pipe on the low pressure end (thick pipe) cools down.
If the measured value of the evaporator output temperature sender G263 (and thus the system cooling output) is OK:
Compare the measured value for the evaporator output temperature sender G263 to the measured values for the left vent temperature sender G150 and the right vent temperature sender G151.
After 5 minutes, the measured values for G150 and G151 must not be more than 3 °C higher than that for G263.
If the measured value for the evaporator output temperature sender G263 is OK and the measured value for the left vent temperature sender G150 and /or the right vent temperature sender G151 is more than 3°C higher than the measured value for G263, perform the measures to be taken in the event of a temperature increase downstream of the evaporator → Chapter
If the required values are not attained, compare the measured values displayed for G150 and G151 to one another.
- If the measured values for G150 and G151 are OK, check actuation and operation of the left heat regulation valve N175, the right heat regulation valve N176 and the coolant circulation pump V50Chapter and "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- If the measured value for one of the senders ( G150 or G151) is lower than the measured value for G263: Check G263, G150 and G151 for proper installation and contact resistance in the electrical connections. Replace the defective sender if applicable "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051..
Note
- The temperature of the air flow from the „Centre“ dash panel vents can additionally be measured for example using a commercially available thermometer.
- If no fault is found at the left vent temperature sender G150, the right vent temperature sender G151, the left heat regulation valve N175, the right heat regulation valve N176 and the coolant circulation pump V50, perform the measures to be taken in the event of a temperature increase downstream of the evaporator.
- If the air flowing out of the variable temperature centre vent (in „Lo“ setting for driver and front passenger side on front operating and display unit, Climatronic control unit J255) is cooled in the „Cold“ setting and not cooled in the „Warm“ setting, check operation of the left heat regulation valve N175 and the right heat regulation valve N176. "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- If the cooling output on the front passenger side is still adequate, but the values are no longer attained on the driver side, this is an indication of insufficient refrigerant in the refrigerant circuit (stratification in evaporator due to lack of refrigerant).
Problems relating to differences between the temperature of the air emitted from the vents with an identical setting in air conditioner control mode may be due to the following:
- Cold or warm air flaps in air ducts not closing fully or not attaining end position → Chapter and "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- Air in one or both heat exchangers (different flow through heat exchangers and uneven heat distribution) → Chapter
- Detachment of foam seal on heat exchanger installation, allowing air to flow past heat exchanger.
Under certain operating conditions residual moisture in the refrigerant circuit may lead to the formation of ice on the compressor regulating valve. Such ice formation impairs compressor control, the evaporator is cooled excessively and ices up. Icing-up of the evaporator may give rise to the following problems:
Repeated or sporadic failure of the air conditioner (no cooling/heat output) after a long journey; the air conditioner functions properly again after a short delay following engine shutoff.
Misting up of the windows on the inside after a long journey; the windows are initially not cleared even by pressing the „Defrost“ button; the air conditioner functions properly again after a short delay following engine shut-off.
Remedy:
Check the measured value of the evaporator output temperature sender G263 („Reading measured value block“ function) "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- If the sender measured value is too high under the usage conditions described by the customer (greater than e.g. 10 °C although air conditioner is functioning properly), check the evaporator output temperature sender G263 (incorrect measured value can cause evaporator to ice up).
- If the sender measured value is too low under the usage conditions described by the customer (at ambient temperature above 0 °C, colder than 0 °C for lengthy period), there is a fault in the refrigerant circuit. The vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a (inform the workshop of the problem).
- Check the refrigerant line from the evaporator to the reservoir (thick pipe, low pressure end) with the engine running. If this line is severely iced up when the problem occurs (a thin layer of ice is permissible), this is also an indication that the temperature in the evaporator is too low (compressor control may not be OK). The vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134a (inform the workshop of the problem).
- Inform the workshop of the problem encountered. The necessary work can only be performed by such specialists (draining of refrigerant circuit, replacement of reservoir and subsequent evacuation of refrigerant circuit for at least 3 hours) Air conditioner with refrigerant R134a.
Parts & tools for this job For 2002 Audi A8