Calibrating reversing camera system
- Make
- Audi
- Model
- A8 D3
- Year
- 2002–2010
- Section
- Reversing camera system › Calibrating reversing camera system
Calibrating reversing camera system
After performing service work on the vehicle it might be necessary to re-calibrate the system of the reversing camera. This might be required after:
- Removing and installing reversing camera R189
- Renewing reversing camera system control unit J772
- Performing accident repair work on rear lid
- Performing repair work on rear axle


The vehicle must be standing on a firm and even surface in order to perform calibration. Make sure nobody is inside the vehicle when performing calibration. Do not move the vehicle and do not open or close any of the vehicle doors when performing calibration. The rear lid must be closed.
Connect up Vehicle diagnosis, testing and information system VAS 5051.
Move steering angle sender G85 to 0 position (wheels in straight-ahead position).

- Wheel centre mounting VAS 6350/1
- Wheel centre mounting VAS 6350/1
- Locating bracket (right-side)
Mounting for spacing laser VAS 6350/2 - Plastic foot
Three on underside of calibration unit VAS 6350/4
Adjustable, for aligning horizontal position of calibration unit VAS 6350/4 - Linear laser VAS 6350/3
On calibration unit VAS 6350/4
Switching on and off Owner's Manual - Spacing laser VAS 6350/2
Operating instructions Owner's Manual - Spirit level
On calibration unit VAS 6350/4
For checking horizontal position - Locating bracket (left-side)
Mounting for spacing laser VAS 6350/2 - Calibration unit VAS 6350/4
(Dimension A) = 1.47 m to 1.90 m between locating brackets of calibration unit VAS 6350/4 and wheel centre mountings VAS 6350/1
Check the bolt hole circle pattern on the wheels.
Prepare wheel centre mountings VAS 6350/1 as required.
To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.
Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.
Fit wheel centre mountings VAS 6350/1 onto wheel bolts on rear wheels.
The wheel centre mountings VAS 6350/1 are kept in position by the O-rings in the adapters.

Note
- When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any “anti-theft” wheel bolts that might be installed.
Using clamping bolts adjust paddles so that they are free to move just slightly above the ground.
Make sure the paddles can move freely.
Position calibration unit VAS 6350/4 behind vehicle at a distance of 1.47 m to 1.90 m from rear wheels; refer to (dimension A) in overview Anchor.
Move calibration unit VAS 6350/4 to a horizontal position.
Turn plastic feet beneath calibration unit VAS 6350/4 to make air bubble in spirit level move exactly to centre of display (arrow).

Warning Make sure no light is reflected on calibration unit VAS 6350/4.
Reflected light impairs the view of the reversing camera R189 and therefore it may be impossible to perform calibration.
Switch on linear laser VAS 6350/3(1) on calibration unit VAS 6350/4 and align entire calibration unit VAS 6350/4 so that laser beam of linear laser VAS 6350/3 hits centre of Audi rings on rear of vehicle.

Check whether Audi rings are in the centre on rear of vehicle; readjust laser beam accordingly.
Switch on the spacing laser VAS 6350/2 with the ON button.
The following display appears and the spacing laser VAS 6350/2 will be switched on.

Hold spacing laser VAS 6350/2(2) flush with bracket on one side of calibration unit VAS 6350/4 as shown in illustration. Spacing laser VAS 6350/2 must make firm contact with bracket.

Make sure laser beam from spacing laser VAS 6350/2 hits lower, larger part of paddle (1).
If this is not the case, position of paddles must be corrected accordingly using clamping bolts on wheel centre mounting VAS 6350/1.
Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350/4 with one hand while laser beam is visible on paddle.
Briefly operate the ON button to measure distance.
Display readout

Make a note of the displayed value.
Perform same measuring procedure for rear wheel on other side of calibration unit VAS 6350/4.
Measured distance value must be identical on both sides.
If values are not identical:
Adjust calibration unit VAS 6350/4 until values on both sides are identical.
When adjusting calibration unit VAS 6350/4, make sure that linear laser VAS 6350/3 on calibration unit VAS 6350/4 still hits centre of Audi rings and spirit level display also remains in the centre. If necessary, readjust.
Measure height of calibration unit VAS 6350/4: dimension (H) (top edge of platform - floor).

Now enter measured distance value and height in vehicle diagnostic, testing and information system VAS 5051B in “millimetres”.
Select “Guided Functions” in vehicle diagnostic, testing and information system VAS 5051B.
In “Vehicle selection” menu, select the relevant data for the vehicle.
Select “Reversing camera system”.
Select “Functions”.
Select “Calibration”.
Further assistance is given by vehicle diagnostic, testing and information system VAS 5051B when continuing with calibration procedure.
Warning Make sure no light is reflected on calibration unit VAS 6350/4.
Reflected light impairs the view of the reversing camera R189 and therefore it may be impossible to perform calibration.
Parts & tools for this job For 2002 Audi A8
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.