Removing and installing battery
- Make
- Audi
- Model
- A8 D3
- Year
- 2002–2010
- Section
- Battery › Removing and installing battery
Removing and installing battery
Warning
- On vehicles with telematics system, activate service mode for telematics control unit in “Guided Functions” before disconnecting battery Vehicle diagnostic tester.
Switch off ignition and take out ignition key.
Remove cover for luggage compartment side trim (right-side) (arrows).

Remove covers (1) and (2) above battery.

Connect battery charger to provide back-up power supply → Chapter.

Disconnect earth cable (2) and positive cable (4) at battery.
Disconnect hose (3) for central gas venting system.
Unscrew bolt (1) on battery retainer plate.
Lift battery out of luggage compartment (right-side).
Warning Observe environmental requirements.
- When disposing of used batteries, always observe the required disposal procedures for batteries and sulphuric acid Electrical system; General informationRep. gr.27Battery.
Installation is carried out in the reverse order; note the following:
Note
- We recommend using the battery indicated in the electronic parts catalogue to ensure optimum operation of the energy management control unit J644.
- Batteries from the Audi parts range feature a base strip adapter for matching to different retainer flanges. The battery operating instructions give details of when and how to use the base strip adapter.
Insert battery in battery carrier so that lug at rear of battery carrier (arrow) engages in recess in battery base strip (1).

Secure battery retainer plate with bolt (1).

Note
- Lug on battery retainer plate must engage in recess on battery base strip.
Connect up battery in the following sequence with ignition and electrical equipment switched off:
First connect battery clamp (4) of positive cable by hand to positive battery terminal “+” and tighten nut.
Attach battery clamp (2) on earth cable to negative battery terminal “–” by hand and tighten nut.
Attach hose (3) for central gas venting system.
Check that battery is firmly secured following installation.
Switch off back-up power supply from battery charger.
If the battery is renewed, the new battery must be adapted Vehicle diagnostic tester.
Vehicle diagnostic tester is connected.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 27 - Starter, current supply
- Electrical components
- A - Adapt battery after replacing
Further instructions are given by Vehicle diagnostic tester.
If battery was removed and installed without back-up power supply, perform following procedures after connecting the battery:
- Deactivate service mode for telematics control unit in “Guided fault-finding”.
- Activate automatic open/close function of electric window regulators - see Owner's Manual.
- Turn the ignition key in ignition lock once to the left as far as the stop.
- Synchronise spare keys and additional keys to ensure correct remote control operation.
- Interrogate event memories of all control units and erase “Low voltage” event if displayed Vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
Energy management control unit J644 must be re-encoded if the battery is renewed Vehicle diagnostic tester.
| Component | Nm |
|---|---|
| Bolt to retainer plate | 24 |
| Battery clamp to battery terminal | 6 |
Parts & tools for this job For 2002 Audi A8
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner