Calibrating rear overhead view camera R246
- Make
- Audi
- Model
- A8 D4
- Year
- 2010–2017
- Section
- Overhead view camera › Calibrating rear overhead view camera R246
Calibrating rear overhead view camera R246
Rear overhead view camera R246 is installed in handle in rear lid.
Special tools and workshop equipment requiredCalibration unit VAS 6350

Ensure requirements are met Anchor.
Set up and align calibration unit VAS 6350 with calibration unit for overhead view camera VAS 6350/6Chapter“Setting up and aligning calibration unit VAS 6350 with calibration unit for overhead view camera VAS 6350/6”.
Connect Vehicle diagnostic tester.
Fit wheel centre mounting VAS 6350/1:
Check bolt circle of wheels.
Prepare wheel centre mountings VAS 6350/1 as required. Use spacers.
To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.
Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.
Fit wheel centre mountings VAS 6350/1 onto wheel bolts on rear wheels.
The wheel centre mountings VAS 6350/1 are kept in position by the O-rings in the adapters.

Note
- When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any “anti-theft” wheel bolts that might be installed.
Use clamping bolts to adjust paddles so that they are free to move just slightly above the ground. Make sure the paddles can move freely.
Alignment of calibration unit VAS 6350 with calibration unit for overhead view camera VAS 6350/6:
After setting up calibration unit VAS 6350 with calibration unit for overhead view camera VAS 6350/6(2), position it centrally between 400 mm and 600 mm (dimension B) at rear of the vehicle (behind rear bumper cover).

Move calibration field of calibration unit VAS 6350 to a horizontal position.
To do so, turn plastic feet beneath calibration field of calibration unit VAS 6350 to make air bubble in spirit level move exactly to centre of display (arrow).

Warning Make sure no light is reflected on calibration unit for overhead view camera VAS 6350/6.
Reflected light impairs the view of the cameras and therefore it may be impossible to perform calibration.
Secure linear laser VAS 6350/3(4) centrally at the location provided on the calibration field of calibration unit VAS 6350.

Switch on linear laser VAS 6350/3(4) on calibration field of calibration unit VAS 6350 and align entire calibration unit VAS 6350 with calibration unit for overhead view camera VAS 6350/6 so that beam of linear laser VAS 6350/3 shines onto centre of Audi rings on rear of vehicle.
Check whether the Audi rings are in the centre on the rear of the vehicle and adjust the laser beam accordingly.
Measuring gap:
Switch on spacing laser VAS 6350/2.
The following display will appear:
The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

Hold spacing laser VAS 6350/2(2) on one side of calibration unit VAS 6350 so that rear edge is flush at bracket. Spacing laser VAS 6350/2(2) must make firm contact with bracket.

Briefly press the measurement button.
The laser will switch on.
Make sure that laser beam from spacing laser VAS 6350/2(2) hits lower, larger part of paddle (1).
If this is not the case, position of paddles must be corrected accordingly using clamping bolts on wheel centre mounting VAS 6350/1.
Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350 with one hand while laser beam is visible on paddle.
Now press measurement button briefly to measure distance.
Perform same measuring procedure for rear wheel on other side of calibration unit VAS 6350.
Measured distance value must be identical on both sides.
If values are not identical:
Adjust calibration field of calibration unit VAS 6350 until values on both sides are identical.
When adjusting calibration field of calibration unit VAS 6350, make sure that linear laser VAS 6350/3 on calibration unit VAS 6350 still hits centre of Audi rings and spirit level display also remains in the centre. Correct if necessary.
Make a note of the dimension measured.
Measuring dimension (h):
Measure height of calibration unit VAS 6350(2) (dimension (h)) from top surface of calibration field of calibration unit VAS 6350(2) (not aluminium frame) to floor. Perform the measurement at the hole provided in the calibration field of the calibration unit VAS 6350(2).

Ensure that spacing laser VAS 6350/2(1) is correctly adjusted (position at front edge).
The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

Now enter measured distance value (h) and dimension in millimetres in Vehicle diagnostic tester.
Vehicle diagnostic tester is connected.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 6C - Control unit for overhead view camera | J928
- 6C - Control unit for overhead view camera, functions
- 6C - Calibration (Rep. gr. 91)
Further instructions are given by Vehicle diagnostic tester during calibration procedure.
Warning Make sure no light is reflected on calibration unit for overhead view camera VAS 6350/6.
Reflected light impairs the view of the cameras and therefore it may be impossible to perform calibration.
Parts & tools for this job For 2010 Audi A8
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.