01 Technical data for engines02 8-cylinder direct injection engine (4.2 ltr. 4-valve)03 Fuel supply system, petrol engines04 8-cylinder TDI engine (4.2 ltr. 4-valve common rail)05 Fuel supply system, diesel engines06 6-cylinder direct injection engine with supercharger (3.0 ltr. 4-valve TFSI)07 6-cylinder TDI engine (3.0 ltr. 4-valve common rail)08 12-cylinder direct injection engine (6.3 ltr. 4-valve FSI)09 8-cylinder direct injection engine (4.0 ltr. 4-valve TFSI)10 Direct injection and ignition system (8-cyl. 4.0 ltr. 4-valve TFSI)11 4-cylinder direct injection engine (2.0 ltr. 4-valve TFSI - generation II)12 6-cylinder direct injection engine (2.5 ltr. 4-valve FSI)13 6-cylinder direct injection engine (evo) with supercharger (3.0 ltr. 4-valve TFSI)14 A8 Security, fuel supply system, petrol engines15 Rear final drive 0BC, 0BD, 0BE, 0BF16 8-speed automatic gearbox 0BK, front-wheel drive and four-wheel drive17 8-speed automatic gearbox 0BL, four-wheel drive18 8-speed automatic gearbox 0BW hybrid, front-wheel drive19 Running gear: Specifications for testing the braking force (according to German legislation)20 Running gear: Trailer Operation Guide21 Running gear: Wheel/Tyre Guide22 Running gear, front-wheel drive and four-wheel drive23 Brake system24 A8 Security, Running gear / brakes25 Heating and air conditioning: Auxiliary heater, supplementary heater26 Heating, air conditioning27 Electrical: Basic information on high-voltage vehicles28 Electrical: Communication29 Electrical system30 Electrical system, hybrid31 A8 Security Electrical system/Communication32 General body repairs, exterior33 General body repairs, interior34 A8 Security body
Audi A8 D4 (2010-2017)28 · Electrical: Communication
28 · Electrical

Calibrating reversing camera

Make
Audi
Model
A8 D4
Year
2010–2017
Section
Reversing camera system › Calibrating reversing camera
Electrical: CommunicationCalibrating reversing camera

Calibrating reversing camera

Ensure requirements are met Anchor.

Connect Vehicle diagnostic tester.

Fit wheel centre mounting VAS 6350/1:

Check bolt circle of wheels.

Prepare wheel centre mountings VAS 6350/1 as required. Use spacers.

To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.

Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.

Fit wheel centre mountings VAS 6350/1 onto wheel bolts on rear wheels.

The wheel centre mountings VAS 6350/1 are kept in position by the O-rings in the adapters.

N94-10685

Note

  • When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any “anti-theft” wheel bolts that might be installed.

Use clamping bolts to adjust paddles so that they are free to move just slightly above the ground. Make sure the paddles can move freely.

Set up and align calibration unit VAS 6350Chapter.

Measuring gap:

Switch on spacing laser VAS 6350/2.

The following display will appear:
A91-12101

The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

A91-12100
Position at front edgePosition at rear edge

Hold spacing laser VAS 6350/2(2) on one side of calibration platform so that it is flush at bracket (position rear edge against bracket). Spacing laser VAS 6350/2(2) must make firm contact with bracket.

N94-10684

Briefly press the measurement button.

The laser will switch on.

Make sure that laser beam from spacing laser VAS 6350/2(2) hits lower, larger part of paddle (1).

If this is not the case, position of paddles must be corrected accordingly using clamping bolts on wheel centre mounting VAS 6350/1.

Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350 with one hand while laser beam is visible on paddle.

Now press measurement button briefly to measure distance.

Note down the measured value.

Perform same measuring procedure for rear wheel on other side of calibration unit VAS 6350.

Measured distance value must be identical on both sides.

If values are not identical:

Adjust calibration unit VAS 6350 until values on both sides are identical.

When adjusting calibration unit VAS 6350, make sure that linear laser VAS 6350/3 on calibration unit VAS 6350 still hits centre of Audi rings and spirit level display also remains in the centre. Correct if necessary.

Measuring dimension (H):

Measure height of calibration unit VAS 6350: dimension (H) (top edge of platform - floor).

A91-11140

Ensure that spacing laser VAS 6350/2 is correctly adjusted (position at front edge).

The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

A91-12100
Position at front edgePosition at rear edge

Now enter measured distance value and height in millimetres in Vehicle diagnostic tester.

Performing calibration

Vehicle diagnostic tester is connected.

Select Diagnosis mode and start diagnosis.

Select Test plan tab.

Select Own test then the following options one after the other:

  • Body
  • Electrical system
  • 01 - Self-diagnosis compatible systems
  • 6C - Reversing camera system/J772
  • 6C - Reversing camera system control unit, functions
  • 6C - Calibration (Rep. gr. 91)

Further instructions are given by Vehicle diagnostic tester during calibration procedure.

Warning Make sure no light is reflected on calibration platform.
Reflected light impairs the view of the reversing camera R189 and therefore it may be impossible to perform calibration.