Calibrating matrix LED headlights with headlight adjustment unit VAS 5209B
- Make
- Audi
- Model
- A8 D4
- Year
- 2010–2017
- Section
- Headlights › Calibrating matrix LED headlights with headlight adjustment unit VAS 5209B
Calibrating matrix LED headlights with headlight adjustment unit VAS 5209B
Note
- The matrix LED headlights are calibrated with the vehicle diagnostic testerVehicle diagnostic tester.
- The dipped headlights are adjusted first in this procedure. Afterwards the matrix main beam function is calibrated.

Note
- The software version of the headlight adjustment unit VAS 5209B must be V 0.80 or above to calibrate the matrix main beam function.

Align VAS 5209B to centre of vehicle at a distance of (a) = 100 mm Operating instructions of VAS 5209B.
Ensure that VAS 5209B is parallel with transverse axis of vehicle. To do so, adjust laser beam of VAS 5209B so it hits securing bolts for wing at front left and front right (arrows).

Move VAS 5209B in front of left headlight and perform parallel check again.
Warning Danger of dazzling other road users if headlight adjustment unit is not correctly aligned.
- Take special care to ensure that the headlight adjustment unit is aligned properly. Only after this has been done can you adjust the headlights so that other road users will not be dazzled.
Vehicle diagnostic tester is connected.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 55 - Dynamic headlight range control (MxB) -J431
- 55 - Headlight range control, functions
- 55 - Basic setting matrix beam (Repair Group 94)
Further instructions are given by Vehicle diagnostic tester during calibration procedure. The dipped headlights must be adjusted first in this procedure → Chapter.
During the program, you will be prompted to determine/read off the angle of the inner edge of the segment in the left headlight in the headlight adjustment unit and to enter this into the tester.
Press the “F1” button (arrow) in the main menu of the VAS 5209B to measure the angle.

Indicated on display:

Press and hold left fog light button (arrow) for at least 3 seconds.
Indicated on display:

Enter angle (arrow) of inner edge of reference segment in vehicle diagnostic tester. If necessary, note "+/-" sign.
Press “F4” button (arrow) on VAS 5209B.

During the program, you will be prompted to determine/read off the angle of the inner edge of the segment in the right headlight in the headlight adjustment unit and to enter this into the tester.
Align VAS 5209B to centre of vehicle at a distance of (a) = 100 mm Operating instructions of VAS 5209 B.

Ensure that VAS 5209 B is parallel with transverse axis of vehicle. To do so, adjust laser beam of VAS 5209 B so it hits securing bolts for wing at front left and front right (arrows).

Move VAS 5209 B in front of right headlight and perform parallel check again.
Press the “F1” button (arrow) in the main menu of the VAS 5209 B to measure the angle.

Indicated on display:

Press and hold right fog light button (arrow) for at least 3 seconds.
Indicated on display:

Enter angle (arrow) of inner edge of reference segment in vehicle diagnostic tester. If necessary, note "+/-" sign.
Press “F4” button (arrow) on VAS 5209 B.

After completing calibration, read out event memory and deal with any faults that are present.
Parts & tools for this job For 2010 Audi A8
- PARTReplacement bulbsSearch: Audi A8 2010 bulbs
- TOOLDigital multimeterSearch: automotive digital multimeter
As an Amazon Associate we earn from qualifying purchases.