Checking condensation drain hose
- Make
- Audi
- Model
- A8 D4
- Year
- 2010–2017
- Section
- Battery cooling module › Checking condensation drain hose
Checking condensation drain hose
For all work on vehicles with a high-voltage system, note the additional warning instructions for working on such vehicles → Chapter and Electrical system, hybrid Rep. gr.93General warning instructions for work on the high-voltage system.
For the following steps, work in the vicinity of high-voltage system components is necessary. Therefore, “perform a visual inspection of the high-voltage components and wiring to check for damage”Chapter“Visual inspection of high-voltage components and wiring for damage” and “note general warning instructions for work on the high-voltage system”Electrical system, hybridRep. gr.93General warning instructions for work on the high-voltage system.
Switch off ignition.
- Before starting work on the high-voltage system, a high-voltage technician must isolate the high-voltage system from the supply Electrical system, hybridRep. gr.93De-energising high-voltage system.
- The types of work for which the high-voltage system has to be de-energised are indicated in the instructions for the procedure. For further information, see Electrical system, hybridRep. gr.93General warning instructions for work on the high-voltage system.
Warning DANGER!High voltage can cause fatal injury.
Danger of severe or fatal injuries from electric shock.
- The high-voltage system may only be de-energised by a suitably qualified person (Audi high-voltage technician).
- It must be definitely confirmed that the high-voltage system is de-energised. The system may only be de-energised using the vehicle diagnostic tester via “Guided Fault Finding”.
- The qualified person (Audi high-voltage technician) ensures that the system is de-energised and secured with the locking cap T40262 to prevent anyone from switching it on. Furthermore, the qualified person must also store the ignition key and maintenance connector for high-voltage system TW in a safe place as an additional measure to prevent the system from being switched back on.
- The qualified person (Audi high-voltage technician) marks the vehicle by attaching the appropriate warning signs.
Note
- De-energising high-voltage system:
- Connect vehicle diagnostic tester
- Select Guided Fault Finding mode
- Using the Go to key, select the following menu items in succession
- Function/component selection
- Body
- Electrical system
- Self-diagnosis compatible systems
- 8C - Hybrid battery management -J840
- 8C - Hybrid battery management, functions
- 51 - De-energise high-voltage system (Rep. gr. 93)
Remove luggage compartment floor General body repairs, interiorRep. gr.70Luggage compartment trim panels; Exploded view - luggage compartment floor.
Move battery cooling module to service position → Chapter.
Check condensation drain (3) for dirt (arrow) and proper installation.

Switch on ignition.
After installation, interrogate event memory of operating and display unit (Climatronic control unit J255) and battery regulation control unit J840 and erase any faults displayed Vehicle diagnostic tester in “Guided Fault Finding” mode.
Parts & tools for this job For 2010 Audi A8