Solar panel for sun roof
- Make
- Audi
- Model
- A8 D4
- Year
- 2010–2017
- Section
- General notes › Solar panel for sun roof
Solar panel for sun roof
Note
- Solar mode is only possible with the sun roof closed or tilted. The solar panel (C) converts solar energy into electrical energy, which is supplied to the vehicle electrical system via contacts (A) (at the front edge of the sun roof) and (B) (on the sun roof frame).

- Solar mode is not possible with the ignition on and in auxiliary heating/auxiliary ventilation mode (fresh air blower control unit J126 interrupts connection between solar panel and fresh air blower V2) Current flow diagrams, Electrical fault finding and Fitting locations.
- If the solar mode of the fresh air blower is not required, the function can be deactivated on the front operating and display unit (Climatronic control unit J255) or on the MMI (Multi Media Interface) Owner's Manual and Operating Manual “Infotainment / MMI”.
- Certain air conditioner functions can be switched on and off via the MMI system (Multi Media Interface) using the “A/C” function on the “Car” / “Car systems” menu. In addition, the operation of the air conditioner can also be influenced by the settings on the MMI (Multi Media Interface) in the “A/C” function of the “Car” / “Car systems” menu. Therefore, if there are problems with these components, first check the settings on the MMI Infotainment/MMI Operating Manual.
- The “Reading measured values” function of the Guided Fault Finding routine for J255 indicates how long the fresh air blower V2 has operated in solar mode (in hours) Vehicle diagnostic tester in “Guided Fault Finding” mode.
- The temperature at which “solar roof” is switched on/off can be entered in the J255 via the “Adaption” function Vehicle diagnostic tester in “Guided Fault Finding” mode.
- The fresh air blower control unit J126 is designed so that, when solar mode is active, the fresh air blower V2 is only activated if the solar cells have generated sufficient energy for operation (at present, the minimum voltage must be greater than 2 V to activate the fresh air blower V2).
- The solar cells on the solar roof must generate a voltage greater than 12.3 V (off-load voltage) for the current generated by the solar cells to be connected through from the fresh air blower control unit J126 to the fresh air blower V2. Once the J126 detects a voltage greater than 12.3 V, the V2 is activated until the current generated by the solar cells drops below approx. 2 V (or the ignition, auxiliary ventilation or auxiliary heating is switched on).
- The energy generated by the solar cells C20 is transferred directly to the fresh air blower V2 via the fresh air blower control unit J126. The fresh air blower converts the electrical energy generated into blower output.
- On vehicles with no solar roof, all the control motors of the air conditioner stop in their current positions when the ignition is switched off. However, the fresh air flaps and air recirculation flaps must be set to “fresh air mode” in order to ventilate the passenger compartment in solar mode. On vehicles with a solar panel for the sun roof, J255 is therefore informed that the vehicle is fitted with solar cells by way of the encoding. J255 then sets the flaps in the air conditioning unit to the “fresh-air mode” position after switching off the ignition.
- The fresh air blower control unit J126 interrogates the voltage at the input of the solar cells at regular intervals when the ignition is off (no signal detected by J255) and converts the voltage generated by the solar cells in such a manner that the fresh air blower runs at the maximum possible speed if sufficient solar energy is being generated.
- Contacts (A) and (B) (at the sun roof and sun roof frame) for transferring the electrical energy generated must be clean and free from normal lubricant.

- If necessary, contacts (A) and (B) can be coated with a small quantity of contact grease (electrically conductive preservative and lubricant available from electronics dealers).
- The electrical energy supplied by the solar panel for the sun roof is approx. 12 W with a sunlight penetration of 500 W/m2.
Example:
500 W/m2 (sunlight penetration) x 0.21 m2 (sun roof solar area) x 0.13 (efficiency of solar cells C20) x 0.9 (efficiency of fresh air blower control unit J126).
Move the vehicle into the sun.
Note
- If the weather conditions are not suitable, shine two commercially available 1000 W halogen lamps for example onto the solar panel for the sun roof, maintaining a distance of at least 500 mm from the solar panel for the sun roof. To enable the solar cells C20 to supply sufficient electrical energy to drive the fresh air blower V2, it must be ensured that all sun roof solar cells C20 are evenly and fully illuminated.
- The electrical energy supplied is only approx. 1.5 W on shining halogen lamps onto the solar panel for the sun roof (the fresh air blower V2 rotates but a flow of air is hardly perceptible).
- Depending on the version, the “Reading measured values” function of the Guided Fault Finding routine for J255 indicates the current power output of the solar cells C20 (voltage and current level) immediately after switching off the ignition Vehicle diagnostic tester in “Guided Fault Finding” mode.
Open the “centre” dash panel vents and close all other vents.
Check the setting on J255 or the MMI (Multi Media Interface). The “solar mode” function must have been set Owner's manual and Operating instructions for “Infotainment / MMI”.
Close sunroof.
Switch off the ignition ( J255 not illuminated).
A current of air can be felt from the dash panel vents (moisten palm of hand to check if necessary).
If no current of air can be felt:
Interrogate the event memory of J255 and check the encoding of J255Vehicle diagnostic tester in “Guided Fault Finding” mode.
Check the setting (and, if applicable, the adaption) on J255 and on the MMI (the “Solar mode” function must be activated) Owner's Manual, Operating instructions for “Infotainment / MMI” and Vehicle diagnostic tester in “Guided Fault Finding” mode.
Move the front right seat (front passenger's seat) as far back as it will go.
Switch off ignition.
Remove the screw-type clip (A).

Unfasten the insulating mat (B) from the bracket (C) and detach.
Note
- To facilitate installation, the glove compartment (D) is provided with lugs with hooks (A) which are engaged as shown in the insulating mat (B) openings on fitting. If the glove compartment (D) has not been correctly installed (lugs with hooks (A) pressing against insulating mat (B) from underneath), the insulating mat (B) can only be removed after taking out the glove compartment General body repairs, interiorRep. gr.68Shelves/storage compartments/covers; Removing and installing glove compartment.

Unplug the connector (A) from the fresh air blower control unit J126(B).

Measure the voltage between contact (2) (of the solar panel for the sun roof) and contact (1) (earth) at the connector (A)Current flow diagrams, Electrical fault finding and Fitting locations.
- Specification: greater than 12.3 V (depending on intensity of sunlight)
Connect up a test lamp (12 V, max. 5 W) between contacts (2) and (1) at the connector (A)Current flow diagrams, Electrical fault finding and Fitting locations.
The test lamp glows or lights (depending on sunlight intensity).
Note
- For the current generated by the solar cells of the solar panel for the sun roof to be switched from the fresh air blower control unit J126 to the fresh air blower V2, the voltage generated by the solar cells must be greater than approx. 12.3 V (no-load voltage). Once J126 has detected a voltage greater than approx. 12.3 V, V2 is activated as long as the voltage supplied by the solar cells remains in excess of roughly 2 V (or the ignition, auxiliary ventilation or auxiliary heating is switched on).
- If the test lamp glows or lights up, the solar panel for the sun roof is functioning properly. If the fresh air blower does not run, check V2 for freedom of movement as well as activation of J126 by the front operating and display unit (Climatronic control unit J255) Vehicle diagnostic tester in “Guided Fault Finding” mode.
- If the test lamp does not glow or light, check the wiring to the two contacts at the sun roof opening. Check solar panel if no fault is found Current flow diagrams, Electrical fault finding and Fitting locations.
- The electrical energy supplied is only approx. 1.5 W on shining halogen lamps onto the solar panel for the sun roof (the fresh air blower rotates but a flow of air is hardly perceptible).
- Depending on the version of the J255, the current supplied by the sun roof with solar cells C20 to the fresh air blower V2 can be read out in the “Reading measured values” function of the Guided Fault Finding routine. Position the vehicle with the sunroof closed in the sun for example (or under two lamps as described above) and then select the corresponding measured value of J255Vehicle diagnostic tester in “Guided Fault Finding” mode. After switching off the ignition, the display shows the current supplied by the sun roof with solar cells C20 on switching off the ignition (and for a short time afterwards).