Safety precautions when handling refrigerants
- Make
- Audi
- Model
- A8 D4
- Year
- 2010–2017
- Section
- Safety precautions › Safety precautions when handling refrigerants
Safety precautions when handling refrigerants
The components and piping system of the air conditioner are filled with the following refrigerant:
This refrigerant is currently known in Germany by the trade names R134a, H-FKW 134a, SUVA 134a and KLEA 134a (other trade names may be used in other countries).
The following safety measures are to be observed in Germany for this refrigerant (additional regulations may apply in other countries).
Warning Refrigerant is a potential health hazard
- Always drain the refrigerant circuit before performing repair work with the circuit open Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
- Only work on the refrigerant circuit in well ventilated areas. Care should be taken to ensure that there are no inspection pits, shafts or cellar entrances within a radius of 5 metres.
Warning Risk of asphyxiation from refrigerant/air mixture if refrigerant escapes.
- Switch on the exhaust gas extraction system.
- Escaping refrigerant is colourless, odourless, heavier than air and displaces oxygen. Should refrigerant gas escape, there will be a previously imperceptible risk of asphyxiation in poorly ventilated areas and inspection pits.
- Smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant. The high temperature of a naked flame or hot objects causes refrigerant gas to undergo chemical decomposition. The resultant decomposition products are toxic.
- Keep an eye bath to hand.
- If liquid refrigerant comes into contact with the eyes, rinse them thoroughly with water for about 15 minutes.
- Then apply eye drops and consult a doctor immediately, even if you do not experience any pain in the eyes.
- Inform the doctor of the type of refrigerant which caused the frostbite.
- Wear rubber gloves to protect the hands.
- Wear safety goggles to protect the eyes.
- If liquid refrigerant comes into contact with other parts of the body, rinse these thoroughly with cold water for about 15 minutes.