A8L V8-4.2L (BFM) (2004)
Indicated on display of VAS 5051:
^
Request in display zone -1- "Enter adaption value. Value: 065535".
^
Display zone -2- shows a keyboard.
-
Enter the measured pad thickness in display zone -2- via the keyboard and confirm entry with "key Q":
Indicated on display of VAS 5051:
^
Zone -3- displays the newly entered pad thickness value indicated by the sliding bar.
-
Store the new pad thickness by pressing key -5-.
Indicated on display of VAS 5051:
^
Request in display zone -1- to "Store channel 6".
^
Zone -2- displays the specified pad thickness limits.
^
Zone -3- displays the former and the newly entered pad thickness value.
-
Confirm and store the new pad thickness by pressing key 4-.
^
Display zone -1- indicates "Store channel 6 Value 0...23 stored".
-
Terminate self-diagnosis and switch ignition off.
-
Mount wheels
-
Check brake fluid level and top off if necessary.