Using cables from V.A.G 1594 connector test kit, connect V.A.G 1527 voltage test lamp between terminals 1 and 2.

-

Operate starter and test activation of fuel injector.

Voltage test lamp must blink respectively.
-

If voltage test lamp does not light up, connect V.A.G 1598/31 test box to wiring harness for Engine Control Module (ECM)  See: Computers
and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting

-

Check wire connection between terminal 2 of connector from respective fuel injector and Engine Control Module (ECM) for continuity or
short circuit to B+:

Terminal 2 on

V.A.G 1598/31 test box

connector of fuel

or Engine Control

injector

Module (ECM)

Cylinder 1 Fuel Injector -N30-

96

Cylinder 2 Fuel Injector -N31-

19

Cylinder 3 Fuel Injector -N32-

113

Cylinder 4 Fuel Injector -N33-

88

Cylinder 5 Fuel Injector -N83-

97

Cylinder 6 Fuel Injector -N84-

112

Cylinder 7 Fuel Injector -N85-

24

Cylinder 8 Fuel Injector -N86-

89

-

Repair open circuit in wiring or short circuit if necessary.

-

If voltage supply and activation are OK, replace Engine Control Module (ECM) and generate readiness code again.