In selection - 1 -, click on the function " 03 - output Diagnostic Test Mode (DTM)".

-

Press -> button repeatedly until Exhaust Flap Valve 2 (N322) is activated.

‹› The actuation rod of the left exhaust flap must move itself on and off.

-

End function "03 - output Diagnostic Test Mode (DTM)" by pressing <- button.

-

Select "06 - End Output".

-

Switch off ignition.

If actuator rod does not move:

-

Check exhaust flap vacuum reservoir => [ Exhaust Flap Vacuum Diaphragm, Checking ] See: Exhaust Pressure Regulator Vacuum
Solenoid/Testing and Inspection.

-

Check vacuum line from vacuum reservoir to the corresponding exhaust flap valve at rear on vehicle floor.

-

Check Exhaust Flap Valve 1 (N321) and (N322) using "Guided Fault Finding".