audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Exhaust Pressure Regulator Vacuum Solenoid > < Exhaust Flaps, Checking|Page 6075
Page 1
background image

Active Exhaust System Actuator: Testing and Inspection
Exhaust Flap Vacuum Diaphragm, Checking

Exhaust Flap Vacuum Diaphragm, Checking

Special tools, testers and auxiliary items required

‹› Hand vacuum pump (V.A.G 1390)

Test Sequence

-

Disconnect hose on vacuum diaphragm for exhaust flap at rear muffler. 

-

Connect hand vacuum pump (V.A.G 1390) to vacuum diaphragm.

-

Generate vacuum using hand vacuum pump.

‹› Linkage must move upward.

-

Vent hand vacuum pump.

‹› Linkage must move downward.

If linkage does not move:

-

Check linkage for ease of movement and check the vacuum diaphragm for leaks.

Exhaust Pressure Regulator Vacuum Solenoid > < Exhaust Flaps, Checking|Page 6075