Housing Assembly HVAC: Removal and Replacement
Installing

Installing

Installation is carried out in the reverse order, when doing this note the following:

-

Replace seal - A - between plenum chamber and A/C unit.

NOTE:
-

Check other seals, replace if necessary Parts Catalog

-

Connect coolant hoses to heater core accurate to side.

-

Secure all hose connections with standard hose clamps or clips as used in series production, or approved replacement parts Parts Catalog

-

When inserting A/C unit, make sure that wiring to actuators (in plenum chamber) and seal - A - is not jammed or damaged by studs.

-

Check damper element - C - for proper seating.

-

After installation, check grommet between engine compartment and plenum chamber for proper seating.

-

Seal 4 bolts - A - (left and right) in plenum chamber (e.g. using Terolan D 511 500 A2). Parts Catalog

-

Check the evaporator drain hoses for proper seating.