01 4-cylinder direct injection engine (1.8 ltr., 2.0 ltr. 4V TFSI, generation II)02 Fuel supply system, petrol engines03 4-cylinder direct injection engine (1.4 ltr. 4-valve TFSI EA 211)04 4-cylinder direct injection engine (1.8 ltr., 2.0 ltr. 4V TFSI, generation III)05 4-cylinder TDI engine (2.0 ltr. 4-valve common rail EA 189 - generation II)06 Fuel supply system, diesel engines07 5-cylinder direct injection engine (2.5 ltr. 4-valve TFSI)08 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)09 Technical data for engines10 Rear final drive 0AY, 0BR, 0BS, 0CR11 Servicing 6-speed manual gearbox 02Q, 0BB, 0FB12 7-speed dual clutch gearbox 0BH (S tronic)13 6-speed manual gearbox 02Q, 0BB14 6-speed manual gearbox 0A615 6-speed dual clutch gearbox 02E16 Running gear: Specifications for testing the braking force (according to German legislation)17 Running gear: Trailer Operation Guide18 Running gear, axles, steering19 Brake system20 Running gear: Wheel/Tyre Guide21 Heating, air conditioning22 Electrical system23 Electrical: Communication24 General body repairs, exterior25 General body repairs, interior
Audi Q3 8U (2011-2018)23 · Electrical: Communication
23 · Electrical

Calibrating reversing camera R189

Make
Audi
Model
Q3 8U
Year
2011–2018
Section
Reversing camera system › Calibrating reversing camera R189
Electrical: CommunicationCalibrating reversing camera R189

Calibrating reversing camera R189

Ensure requirements are met Anchor.

Connect Vehicle diagnostic tester.

Fit wheel centre mounting VAS 6350/1:

Check bolt circle of wheels.

Prepare wheel centre mountings VAS 6350/1 as required. Use spacers.

To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.

Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.

Fit wheel centre mountings VAS 6350/1 onto wheel bolts on rear wheels.

The wheel centre mountings VAS 6350/1 are kept in position by the O-rings in the adapters.

N94-10685

Note

  • When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any “anti-theft” wheel bolts that might be installed.

Use clamping bolts to adjust paddles so that they are free to move just slightly above the ground. Make sure the paddles can move freely.

Set up and align calibration unit VAS 6350Chapter.

Measuring gap:

Switch on spacing laser VAS 6350/2.

The following display will appear:
A91-12101

The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

A91-12100
Position at front edgePosition at rear edge

Hold spacing laser VAS 6350/2(2) on one side of calibration platform so that it is flush at bracket (position rear edge against bracket). Spacing laser VAS 6350/2(2) must make firm contact with bracket.

N94-10684

Briefly press the measurement button.

The laser will switch on.

Make sure that laser beam from spacing laser VAS 6350/2(2) hits lower, larger part of paddle (1).

If this is not the case, position of paddles must be corrected accordingly using clamping bolts on wheel centre mounting VAS 6350/1.

Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350 with one hand while laser beam is visible on paddle.

Now press measurement button briefly to measure distance.

Note down the measured value.

Perform same measuring procedure for rear wheel on other side of calibration unit VAS 6350.

Measured distance value must be identical on both sides.

If values are not identical:

Adjust calibration unit VAS 6350 until values on both sides are identical.

When adjusting calibration unit VAS 6350, make sure that linear laser VAS 6350/3 on calibration unit VAS 6350 still hits centre of Audi rings and spirit level display also remains in the centre. Correct if necessary.

Measuring (dimension H):

Measure height of calibration unit VAS 6350: (dimension H) (top edge of platform - floor).

A91-11140

Ensure that spacing laser VAS 6350/2 is correctly adjusted (position at front edge).

The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

A91-12100
Position at front edgePosition at rear edge

Now enter measured distance value and height in millimetres in Vehicle diagnostic tester.

Performing calibration

Vehicle diagnostic tester is connected.

Select Diagnosis mode and start diagnosis.

Select Test plan tab.

Select Own test then the following options one after the other:

  • Body
  • Electrical system
  • 01 - Self-diagnosis compatible systems
  • 6C - Reversing camera system/J772
  • 6C - Reversing camera system control unit, functions
  • 6C - Calibration (Rep. gr. 91)

Further instructions are given by Vehicle diagnostic tester during calibration procedure.

Warning Make sure no light is reflected on calibration platform.
Reflected light impairs the view of the reversing camera R189 and therefore it may be impossible to perform calibration.