Special tools and workshop equipment requiredUltrasound A/C cleaner VAS 6189ACleaning fluid VAS 6189/1Suction nozzle VAS 6288Commercially available vacuum cleanerCheck whether the air conditioning unit evaporator is really the source of the odour by switching from fresh air to air recirculation mode Chapter“Notes on odours in vehicles with air conditioner”.
Check and if necessary clean plenum chamber water drain → Chapter.
Remove dust and pollen filter → Chapter.
Clean installation slot for dust and pollen filter Anchor.
Seal opening for dust and pollen filter at air conditioning unit.
Start engine.
Close windows, sun roof and rear lid.
Open all dash panel vents.

Using rotary air distribution control (4), set direction of air flow to “dash panel vents”.
Activate “air recirculation mode” on operating unit (air conditioning system control unit J301) and switch off air conditioner compressor.
Lamp in button (3) is on.Lamp in button (2) is off.Set lowest possible temperature.
Rotary temperature control (1) on “cold” stopSet rotary fresh air blower control (5) to speed “1”.

Activate “air recirculation mode” on operating unit (Climatronic control unit J255) and switch off air conditioner compressor.
Lamp in button (3) is on.Lamp in button (1) is off.Set lowest possible temperature.
Set temperature using rotary controls (2, 8) – “LO” display for driver and front passenger side in display (6) of J255.Using air distribution button (9), set direction of air flow to “dash panel vents”.
Use fresh air blower button (4) to set lowest blower speed ( V2 running at minimum speed).
Shake bottle of cleaning fluid VAS 6189/1 and pour fluid into ultrasound A/C cleaner VAS 6189A.
Note
- For information on how to use the ultrasound A/C cleaner, refer to the Operating instructions of VAS 6189A.
Position ultrasound A/C cleaner VAS 6189A in front passenger's footwell.
Start up ultrasound A/C cleaner VAS 6189A (in accordance with operating instructions) and position outlet hose so that vapour emerging is drawn in by fresh air blower V2 via opening for air recirculation of air conditioning unit (in passenger's footwell behind glove box).
Close vehicle doors.
Note
- The cleaning process takes approx. 15 to 20 minutes and is completed when no further vapour emerges from the outlet hose of the ultrasound A/C cleaner VAS 6189A.
Switch off ultrasound A/C cleaner VAS 6189A.
Open vehicle doors and vent vehicle for at least 10 minutes.
Remove ultrasound A/C cleaner VAS 6189A from vehicle and clean it.
Switch off ignition.
Install dust and pollen filter → Chapter.
Parts & tools for this job For 2011 Audi Q3
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi Q3 2011 cabin filter
As an Amazon Associate we earn from qualifying purchases.