Working on refrigerant circuit (Heating, air conditioning)
- Make
- Audi
- Model
- Q3 8U
- Year
- 2011–2018
- Section
- Repair instructions › Working on refrigerant circuit
Heating, air conditioningWorking on refrigerant circuit
Working on refrigerant circuit
Warning Risk of injury due to pressure build-up in the air conditioner (exposure to heat).
- Exposure to heat generates considerable pressure in the air conditioning system, which could cause it to burst.
- Welding, brazing and soldering work must not be performed on components of air conditioning system when charged. This also applies to welding and soldering work on the vehicle if there is a danger of air conditioner components becoming hot.
- Renew damaged or leaking components of the air conditioner.
Warning The ingress of moisture will lead to the air conditioner malfunctioning.
- When servicing the air conditioner, re-seal all open components and pipe connections immediately.
- If the air conditioner has been open for a certain amount of time, check components for corrosion and renew if necessary.
Warning
- After the air conditioner compressor is switched off, it might take a relatively long period on this vehicle before the pressure in the high-pressure side drops (the expansion valve is cold and the pressure in the low-pressure side increases rapidly after the compressor is switched off, the expansion valve is closed and the refrigerant can flow to the low-pressure side only slowly).
Parts & tools for this job For 2011 Audi Q3
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi Q3 2011 cabin filter