Removing and installing battery
- Make
- Audi
- Model
- Q5 Mk1
- Year
- 2008–2017
- Section
- Battery › Removing and installing battery
Removing and installing battery

Switch off ignition and take out ignition key.
Take out luggage compartment floor (3).
If fitted, take out dirt tray.
If fitted, remove bass box (2)CommunicationRep. gr.91Sound system; Removing and installing subwoofer R211.
Fold back floor covering (1) over flap.
Release retaining tabs (arrows) and open flap (1).

Note
- The different versions of the flap have different numbers of retaining tabs.
Connect battery charger to provide back-up power supply Electrical system; General informationRep. gr.27Charging battery.
Remove tool kit (2) together with mounting for tool kit.

Open cover (7) over negative battery terminal.
Loosen nut (6) a few turns and disconnect battery clamp of earth cable from battery terminal.
Pull off hose (8) for central gas venting system.
Remove bolts (arrows) on battery retainer plate (1).
Note
- Different versions; for allocation refer to Electronic parts catalogue
Pull battery (5) slightly out of battery retainer.
Open cover (4) over positive battery terminal.
Loosen nut (3) several turns and disconnect battery clamp of positive cable together with fuse holder A SA from battery terminal.
Lift battery out of luggage compartment.
Warning Observe environmental requirements.
- When disposing of used batteries, always observe the required disposal procedures for batteries and sulphuric acid Electrical system; General informationRep. gr.27Battery.
Note
- Only install maintenance-free batteries with the specifications “TL82506” (from December 1997 onwards) and “VW75073” (from August 2001 onwards).
- Batteries from the Audi parts range feature a base strip adapter for matching to different retainer flanges. The battery operating instructions give details of when and how to use the base strip adapter.
Insert battery in battery retainer so that battery base strip engages in the retainer flanges of the battery retainer (arrow).

Place battery retainer plate (1) in position.

Tighten bolts (arrows) for battery retainer plate.
Attach hose (8) for central gas venting system.
Connect up battery (5) in the following sequence with ignition and electrical equipment switched off:
First connect battery clamp (3) of positive cable by hand to positive battery terminal “+” and tighten nut.
Unplug electrical connector (2) at battery monitor control unit J367(item 3).

When connecting battery, attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).
Reconnect connector at battery monitor control unit J367.
Check that battery is firmly secured following installation.
Install cover for battery recess General body repairs, interiorRep. gr.70Luggage compartment trim panels; Exploded view - luggage compartment floor.
If the battery is renewed, the new battery must be adapted Vehicle diagnostic tester.
Vehicle diagnostic tester is connected.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 27 - Starter, current supply
- Electrical components
- A - Adapt battery after replacing
The Vehicle diagnostic tester will guide you through the battery check from here on.
The following measures are required after re-connecting the battery:
- Activate automatic open/close function of electric window regulators - see Owner's Manual.
- Interrogate event memories of all control units and erase “Low voltage” fault display Vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
Parts & tools for this job For 2008 Audi Q5
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
As an Amazon Associate we earn from qualifying purchases.