Workshop Manuals Factory service & repair Audi
01 Technical data for engines02 6-cylinder direct petrol injection engine (3.2 ltr. 4-valve)03 Fuel supply system, petrol engines04 4-cylinder TDI engine (2.0 ltr. 4-valve common rail)05 6-cylinder TDI engine (3.0 ltr. 4-valve common rail)06 4-cylinder direct injection engine (2.0 ltr. 4-valve TFSI - generation II)07 Fuel supply system, diesel engines08 4-cylinder TDI engine (2.0 ltr. 4-valve common rail - generation II)09 6-cylinder direct injection engine with supercharger (3.0 ltr. 4-valve TFSI)10 6-cylinder TDI engine (3.0 ltr. 4-valve common rail - generation II)11 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)12 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)13 6-speed manual gearbox 0B2, four-wheel drive14 Rear final drive 0BC, 0BD, 0BE, 0BF15 Servicing 6-speed manual gearbox 0B2, four-wheel drive16 Servicing 6-speed manual gearbox 0B1, front-wheel drive17 Servicing 7-speed dual clutch gearbox 0B5 (S tronic)18 6-speed manual gearbox 0B1, front-wheel drive19 7-speed dual clutch gearbox 0B5 (S tronic)20 8-speed automatic gearbox 0BK, four-wheel drive21 8-speed automatic gearbox 0BW hybrid, four-wheel drive22 Automatic gearbox 0B6, four-wheel drive23 Running gear: Specifications for testing the braking force (according to German legislation)24 Running gear: Trailer Operation Guide25 Running gear, front-wheel drive and four-wheel drive26 Brake system27 System description - dynamic steering28 System description - steering wheel29 Running gear: Wheel/Tyre Guide30 Heating, air conditioning31 Heating and air conditioning: Auxiliary heater, supplementary heater32 System description - interior lights33 Electrical: System description - exterior lights34 System description - wiper and washer systems35 Electrical: System description - entry and start authorisation36 Electrical: Basic information on high-voltage vehicles37 Electrical: System description - infotainment and navigation system38 Electrical: System description - adaptive cruise control39 System description - infotainment and audio output (MOST)40 Electrical system41 Electrical system, hybrid42 Electrical: Communication43 General body repairs, exterior44 System description - Windows and doors45 General body repairs, interior
Audi Q5 Mk1 (2008-2017)30 · Heating, air conditioning
30 · Heating & A/C

Safety precautions when handling refrigerants

Make
Audi
Model
Q5 Mk1
Year
2008–2017
Section
Safety precautions › Safety precautions when handling refrigerants
Heating, air conditioningSafety precautions when handling refrigerants

Safety precautions when handling refrigerants

The components and piping system of the air conditioner are filled with the following refrigerant:

1.1.1 2-tetrafluoroethane (CF3-CH2F or CH2F-CF3)

This refrigerant is currently known in Germany by the trade names R134a, H-FKW 134a, SUVA 134a and KLEA 134a (other trade names may be used in other countries).

In Germany, observe the following safety measures for this refrigerant (additional regulations may apply in other countries).

The refrigerant circuit must be discharged first should repair work require the refrigerant circuit to be opened → Chapter. All contact with liquid refrigerant or refrigerant vapours should be avoided. Should refrigerant escape although all safety precautions are observed, do not inhale the mixture of refrigerant and air which then forms.

For this reason, switch on existing exhaust gas extraction systems and use rubber gloves and safety goggles.

Reason:

Intensive exposure to refrigerant would cause frostbite on unprotected parts of the body.

Warning Keep an eye-bath to hand.
Should liquid refrigerant come into contact with the eyes, rinse them thoroughly with water for about 15 minutes.
Then apply eye drops and consult a doctor immediately, even if you do not experience any pain in the eyes.
Always inform the doctor of the type of refrigerant involved.

Should refrigerant come into contact with other parts of the body even though all safety precautions have been observed, these components must also be thoroughly rinsed with cold water immediately for at least 15 minutes.

Although refrigerants do not represent a fire hazard, smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant.

Reason:

The high temperature of a naked flame or hot objects causes decomposition of refrigerant gas. Inhalation of the toxic decomposition products causes dry coughing and nausea.