Conditioner, Levers and Connecting Elements ] See: Description and Operation.

-

Remove the screws - E -

-

Remove the mounting plate - F - (together with the control motors, the levers, the cam plates and the connector rods) from the A/C.

Installing

Installation is carried out in the reverse order, when doing this note the following.

-

Apply a small quantity of grease (G 000 150) to the cam plate guides as well as to the pins at the door levers.

-

Make sure the levers, cam plates and connector rod mounting plates -  A - are assembled correctly. Refer to => [ Retaining Plate with Left
Footwell Door Motor and Center Vent Motor ] See: Service and Repair/Retaining Plate with Left Footwell Door Motor and Center Vent Motor.

-

When installing the mounting plate- A -, insert the mounting plate pins - B - into the brackets - C - and the cam plate pins - D - and - F - into the
brackets - E -.

-

When installing the mounting plate - A - insert the lever pins - G - into the guiding groove on the cam plates -  F -.

‹› When inserting, make sure that the cam plate stop - C - is not in area - F - (between both stops on the A/C -  D - and - E -).

‹› The cam plate - A - actuates the door for the left indirect ventilation (driver's side) via the lever - B -.

-

Install the screws - E -.