audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Refrigerant Circuit O-ring Seals|Page 8792 > < Refrigerant Circuit O-ring Seals|Page 8790
Page 3
background image

‹› The couplings - B - and - C - on the refrigerant line - D - with inner heat exchanger must be replaced each time the refrigerant line is opened.

-

Pry the couplings - B - and - C - using a screwdriver - A - out of the refrigerant line -  - with inner heat exchanger - arrow -.

-

Thoroughly clean all parts of the refrigerant line connections (for example, using cleaning solution (D 009 401 04)). 

-

Check the connector - A - for the refrigerant line with inner heat exchanger for damage.

-

Replace the O-ring seals - B, G -, support rings -  C, F - and couplings - D, E -.

‹› Note the installation instructions for O-ring seals. Refer to => [ Refrigerant Circuit O-ring Seals ] See: Service and Repair/Removal and

Replacement/Refrigerant Circuit O-ring Seals.

-

Coat O-ring seals lightly with refrigerant oil before installing. Refer to => [ Refrigerant Circuit O-ring Seals ] See: Service and Repair/Removal
and Replacement/Refrigerant Circuit O-ring Seals.

-

Press on the couplings - D - and - E - until this audibly latch into the refrigerant line with inner heat exchanger connector piece - A -.

-

Thoroughly clean the refrigerant lines - A - and -  B - around the connection area and check for damage.

Refrigerant Circuit O-ring Seals|Page 8792 > < Refrigerant Circuit O-ring Seals|Page 8790