Evaporator Drain Tube > < Customer Interest for Evaporator Core:|871003|Page 8819
Page 7
background image

-

Fill the groove on the A/C unit - E - before installing the separating wall - C - for example with silicone adhesive (D 176 001 A3).

-

Install the separating wall - C -.

‹› The separating wall - C - is included in the replacement evaporator kit.

‹› There are different versions of the separating wall - C - (with and without the spayed on sealing lip).

‹› If the connecting location between the A/C unit - E - and the separating wall - C - is not sealing in area -  D - condensation water from the A/C

could leak into the footwell when, for example, driving around a curve.

-

Remove any excess adhesive (the adhesive may only in the area -  D - ); and remove any excess adhesive out of the groove -  G -.

-

Install the air intake housing. Refer to => [ A/C Unit Air Intake Housing ] See: Air Duct/Service and Repair/A/C Unit Air Intake Housing.

-

Install the remaining removed parts in the opposite order.

-

Reconnect the battery (A) ground connection; when doing this, pay attention to the notes regarding reconnecting the battery.

-

Evacuate the refrigerant circuit and fill it. Refer to => Refrigerant R134a - Servicing.

-

Perform a basic setting and the output Diagnostic Test Mode (DTM).on the A/C system. Refer to => Vehicle Diagnosis, Testing and Information
System VAS 5051 in "Guided Fault Finding" function.

‹› On this vehicle, the control motors are equipped with electronics, during the first basic setting, a new control motor learns its position on the air

conditioner and can then be controlled by the A/C control head climatronic control module (J255) (currently all control motors are identical).
Refer to => Vehicle Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

‹› During the basic adjustment, the control motors are assigned and adapted corresponding to the switching sequence of the wiring. If this sequence

does not conform the specification, the control motors will adapt incorrectly and the door control will be wrong. Refer to => [ A/C Control Motor
Block Diagram ] See: Description and Operation/A/C Control Motor Block Diagram. 

-

Check the A/C control head climatronic control module (J255) Diagnostic Trouble Code (DTC) memory and erase any displayed malfunction if
necessary. Refer to => Vehicle Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

-

Operate the A/C system after filling the refrigerant circuit. Refer to => [ A/C System, Operating after Filling Refrigerant Circuit ] See: Service and
Repair/Procedures/A/C System, Operating after Filling Refrigerant Circuit.

‹› Note the information regarding operating the A/C system after filling. Refer to => Refrigerant R134a - Servicing. 