CAUTION!
Risk of damaging refrigerant lines and hoses.

‹› Do not stretch, kink or bend refrigerant lines and hoses.

-

Remove the bolts - 2 - and - 3 - and remove the refrigerant lines form the compressor.

‹› Close open lines and connections on A/C compressor using suitable caps (to prevent possible penetration of dirt and moisture).

Installing

Installation is done is reverse order, observe the following:

-

Replace the O-ring seals - D - and - C -.

-

Check the guide ring - F - on the connections for both refrigerant lines - B - and - C - for damage. 

-

Clean the refrigerant line and compressor connections and check for damage.

‹› Do not use the O-rings from the sealing caps that are installed on the connections in the replacement compressor when installing the lines.

‹› Note the installation instructions for O-ring seals. Refer to => [ Refrigerant Circuit O-ring Seals ] See: Service and Repair/Removal and

Replacement/Refrigerant Circuit O-ring Seals.

-

Coat O-ring seals lightly with refrigerant oil before installing. Refer to => [ Refrigerant Circuit O-ring Seals ] See: Service and Repair/Removal
and Replacement/Refrigerant Circuit O-ring Seals.

-

Insert the respective O-ring seal - D - and -  E - in the groove - G - on the connections for both refrigerant lines - B - and - C -.