CAUTION!
There is a risk of injury because the fuel is under very high pressure. 

‹› Before opening high pressure area of the fuel injection system, fuel pressure must be relieved to residual pressure.

‹› To reduce remaining residual pressure, lay a clean cloth around the connector and carefully loosen connector.

-

Reduce fuel pressure in high pressure area. Refer to => [ Before Opening High Pressure Fuel Injection System ] See: Engine, Cooling and
Exhaust/Engine/Service Precautions/Before Opening High Pressure Fuel Injection System.

-

Remove threaded connection - 1 -.

-

Loosen union nuts - 2 - and - 3 - by counterholding at the connections.

-

Remove bolts - arrows - on the retaining plates and the high pressure line.

-

Remove high pressure line connections - arrow -. 