audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Injection Pressure Sensor/Switch|Testing and Inspection|Page 4096 > < Air Injection Pressure Sensor/Switch|Testing and Inspection
Page 2
background image

‹› The voltage for the Secondary Air Injection Sensor 1 (G609) is supplied by the Motronic Engine Control Module (ECM) Power Supply Relay

(J271) OK.

-

Using a multimeter, check the Secondary Air Injection Sensor 1 (G609) electrical harness connector terminal 1 for voltage. 

-

Operate the engine briefly.

Specified value: approx. 5 V.

-

Switch the ignition off.

If the specified value was not obtained:

-

Using a multimeter, check the Secondary Air Injection Sensor 1 (G609) electrical harness connector terminal 1 to the Motronic Engine Control
Module (ECM) (J623)terminal 53 for resistance.

Specified value: 1.5 ohms max

If the specification was not obtained:

-

Check the wiring for a short circuit to Battery positive (+) or an open circuit.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.