Q5 Quattro V6-3.2L (CALB) (2009)
‹› Observe bubble level (sight glass) on Calibration Device (VAS 6350) - arrow -.
-
Switch Line Laser (VAS 6350/3) on Calibration Device (VAS 6350) on.
-
Put on laser eye protection.
-
Align the calibration device (VAS 6350) so the line laser (VAS 6350/3) strikes the center of the brand emblem on the rear lid.
-
Check left and right distance between catch bracket on Calibration Device (VAS 6350) and measuring paddle - 1 - on wheel sensors again.
‹› Specified value: 1700 ± 2 mm
Calibration Procedure
The following should not occur during the calibration procedure:
‹› Vehicle doors must not be opened or closed.
‹› People should not sit in the vehicle.
‹› People should not go between the vehicle and the lane change assistance calibration device (VAS 6350/4).
Procedure