Removing and installing battery
- Make
- Audi
- Model
- Q7 Mk1
- Year
- 2006–2015
- Section
- Battery › Removing and installing battery
Removing and installing battery
Special tools and workshop equipment requiredRemoval lever 80 - 200
Warning Vehicles with TDI engine (SCR)
- After the ignition is switched off, the reducing agent is automatically drawn back into the active tank for reducing agent from the metering line going to the injector for reducing agent N474.
- Before working in this area, you must therefore wait until the reducing agent has been completely drawn out of the metering line; this can take up to 10 minutes after the ignition has been switched off.
- For the same reason, it is important to wait until the reducing agent has been drawn back (i.e. 10 minutes) before disconnecting the battery.
Move driver's seat to highest position and as far to the rear as possible, using full range of seat adjustment.
Switch off ignition and take out ignition key.
Remove bolt (2) and lift out footwell vent (1).

Remove rear seat rail cover Rep. gr.72.
Release rear retaining clips (1)(arrow).

Note
- If necessary, use screwdriver to reach into recess of retaining clips and release.
Release retaining clips on rear of cover (1) in direction of arrows (A).

Note
- Illustration shows seat removed.
Then remove cover from driver's seat bracket in direction of arrow (B).
Pry covers (1) and (3) out of floor covering using removal lever 80 - 200.

Unscrew both front bolts (4) at driver's seat bracket and tilt bracket (2) upwards.
Move clear wiring harness for driver's seat.
Note
- Illustration shows seat removed.
Move backrest and seat cushion to front with driver's seat tilted.

Press retaining clips (1)(arrow) and remove cover (2) above battery.
Note
- If necessary, use screwdriver to reach into recess of retaining clips and release.
Connect battery charger to provide back-up power supply → Chapter.

Disconnect earth cable (2) and positive cable (3) at battery.
Disconnect hose (1) for central gas venting system.
Unscrew stud (4) with battery retainer plate.
Unscrew bolt (5) and remove top battery retainer plate (6).
Lift battery out of battery retainer.
Warning Observe environmental requirements.
- When disposing of used batteries, always observe the required disposal procedures for batteries and sulphuric acid Electrical system; General informationRep. gr.27.
Installation is carried out in the reverse order; note the following:
Note
- We recommend using the battery indicated in the Electronic parts catalogue to ensure optimum operation of the energy management control unit J644.
- Batteries from the Audi parts range feature a base strip adapter for matching to different retainer flanges. The battery operating instructions give details of when and how to use the base strip adapter.
Insert battery in battery retainer; the battery base strip must engage in the retainer flanges of the battery retainer (arrows).

Secure top battery retainer plate (6) with bolt (5).

Fit battery retainer plate and tighten stud (4).
Connect up battery in the following sequence with ignition and electrical equipment switched off:
First connect battery clamp (3) of positive cable by hand to positive battery terminal “+” and tighten nut.
Note
- If electrical connector at battery monitor control unit J367 is not attached when connecting battery, make sure to wait 30 seconds before attaching electrical connector.
When connecting battery, attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut.
Connect hose for central gas venting system. Observe notes in Electrical system; General informationRep. gr.27.
After installation, check that battery is securely attached Electrical system; General informationRep. gr.27.
Switch off back-up power supply from battery charger.
If battery is renewed, control unit must be adapted in “Guided Fault Finding” or “Guided Functions” mode vehicle diagnostic tester.
Install driver's seat bracket Rep. gr.72.
If battery was removed and installed without back-up power supply, perform following procedures after connecting the battery:
- Activate automatic open/close function of electric window regulators - see Owner's Manual.
- Synchronise spare keys and additional keys to ensure correct remote control operation. To do so, insert key in ignition lock, switch on the ignition and then off again, then remove the key.
- Interrogate event memories of all control units and erase “Low voltage” entry vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
| Component | Nm |
|---|---|
| Stud with battery retainer plate to battery retainer | 20 |
| Top battery retainer plate to battery retainer | 9 |
| Battery clamp to battery terminal | 6 |
| Footwell vent to battery cover | 2 |
Parts & tools for this job For 2006 Audi Q7
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
As an Amazon Associate we earn from qualifying purchases.