Removing and installing dryer cartridge
- Make
- Audi
- Model
- Q7 Mk1
- Year
- 2006–2015
- Section
- Servicing refrigerant circuit › Removing and installing dryer cartridge
Removing and installing dryer cartridge
Note
- The dryer cartridge is installed in the receiver of the condenser and can be renewed at present without removing the condenser.

- The receiver collects the droplets of liquid and conveys them in a continuous stream to the expansion valve. Moisture which has entered the refrigerant circuit during assembly is collected by the dryer cartridge in the receiver.
- As of Model Year 2006, condensers may have been gradually introduced (introduction not finalised, possibly only for certain versions) on which the receiver is attached with the dryer cartridge to the condenser (similar to Audi A3 as of Model Year 2004 for example Heating, air conditioning Audi A3 2004 >Rep. gr.87). Until further notice, this receiver can only be renewed after removing the condenser. Replace the O-rings (A) and (B) version. Electronic parts catalogue, with the receiver and tighten the bolts in the connection area to 10 Nm.

Drain the refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (air conditioner with refrigerant R134a, refrigerant circuit, working with air conditioner service station).
Remove the cover over the radiator (upper radiator cover) General body repairs, exteriorRep. gr.50.
Remove the upper radiator cover and the radiator cowl with the radiator fans Engine, mechanicsRep. gr.19.
Unfasten the radiator and the condenser from the lock carrier and swivel both these components with the coolant hoses and refrigerant lines connected as far as possible to the rear (disengage and tilt, do not remove radiator, do not open cooling circuit) → Chapter and Engine, mechanicsRep. gr.19
Warning Danger from the escape of pressurised refrigerant.
Frostbite on the skin and other parts of the body.
Extract the refrigerant and then immediately open up the refrigerant circuit.Extract the refrigerant again if more than 10 minutes have elapsed since extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit.
Unscrew the cover (A) and detach it with the seal (B).

Warning
- The refrigerant is to be extracted from the refrigerant circuit before removing the cap (D). Renewed evaporation may create pressure in the refrigerant circuit if the circlip (C) and the cap (D) are not removed within 10 minutes. Extract refrigerant again.
Check the pressure in the refrigerant circuit by way of the pressure gauge of an air conditioner service station for example Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (air conditioner with refrigerant R134a, refrigerant circuit, working with air conditioner service station).
Warning Only remove the circlip (C) if the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure.
Press the cap (D) in arrow direction into the receiver.
Note
- The cap (A) is sealed with two O-rings (C) in the receiver. If these O-rings have dried out in the course of operation, pressing the cap (A) into the receiver and subsequent removal will be difficult. If necessary, clean the inside of the receiver (B) and then moisten it with a small quantity of refrigerant oil

Unfasten and remove the circlip (C).

Screw a cheese-head bolt (currently with M5 thread) into the thread of the cap (D) and use pliers to pull out the cap (D) at the bolt.
Use pointed nose pliers to pull out the dryer cartridge (1) in direction of arrow.

Note
- Re-seal the receiver if applicable. Dirt or moisture could ingress if it is left open for a lengthy period.
Screw out the cap (1) (12 ± 2 Nm).

Warning
- The refrigerant is to be extracted from the refrigerant circuit before removing the cap (1). Renewed evaporation may create pressure in the refrigerant circuit if the cap (1) is not removed within 10 minutes. Draw off the refrigerant again.
- Only remove the cap (1) if the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure.
Use pointed-nose pliers to pull out the dryer cartridge (2) in (arrow direction).
Note
- Re-seal the receiver if applicable. Dirt or moisture could ingress if it is left open for a lengthy period.
Install in reverse order, paying attention to the following:
If necessary, clean the upper area on the inside of the receiver (B) and moisten this with a small quantity of refrigeration oil.

Renew cap (A) with O-rings (C)Electronic parts catalogue.
Moisten the new O-ring (C) of the new cap (A) with a small quantity of refrigeration oil before fitting. Chapter
Take new dryer cartridge (D) out of packaging and install Electronic parts catalogue.
Note
- Never fit desiccant bags which have been exposed to the ambient atmosphere for longer than absolutely necessary and have thus absorbed moisture (e.g. not stored in packaging or packaging damaged) Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner (air conditioner with refrigerant R134a, general information on air conditioner).
- Desiccant bags that have been exposed to the ambient air soon become saturated with moisture and therefore become unusable.
Fit the cap (D) and secure it with the circlip (C).

If necessary, clean the upper area on the inside of the receiver (B) and moisten this with a small quantity of refrigerant oil.

Replace the cap (A) with O-rings (C)Parts catalogue.
Moisten the O-rings (C) of the new cap (A) with a small quantity of refrigerant oil before fitting.
Take the new dryer cartridge (D) out of the packaging and install Parts catalogue.
Note
- Never fit dryer cartridges which have been exposed to the ambient atmosphere for longer than absolutely necessary and have thus absorbed moisture (e.g. not stored in packaging or packaging damaged) Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner (air conditioner with refrigerant R134a, general information on air conditioner).
- Desiccant cartridges which have been exposed to the ambient atmosphere soon become saturated with moisture and thus unusable.
Fit the cap (A) (tightening torque 12 ± 2 Nm).
Re-install remaining components removed before.
Evacuate and re-charge the refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (air conditioner with refrigerant R134a, refrigerant circuit, working with air conditioner service station).
Start up the air conditioner after charging the refrigerant circuit → Chapter
Note
- Also heed the information on start-up of the air conditioner after charging Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner (air conditioner with refrigerant R134a, general information on air conditioner). Before starting up air conditioner after fresh charging.
Parts & tools for this job For 2006 Audi Q7
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi Q7 2006 cabin filter