Calibrating lane change assist
- Make
- Audi
- Model
- Q7 Mk2
- Year
- 2015–2023
- Section
- Lane change assist › Calibrating lane change assist
Calibrating lane change assist
If a software update is required, this must be performed prior to the calibration.Special tools and workshop equipment requiredCalibration unit VAS 6350
The lane change assist control unit J769/ J770 must be calibrated in “Guided Fault Finding” or “Guided Functions” mode Vehicle diagnostic tester under the following conditions:
If lane change assist control unit J769 or lane change assist control unit 2 J770 has been renewed.If the rear bumper cover has been damaged, for instance when parking the car.If the rear bumper cover has been removed and installed.If bolts securing the bumper have been loosened.If the event memory contains the entry “no or incorrect basic setting/adaption”.
- Spacing laser VAS 6350/2
For distance measurement
For use refer to Operating instructions for calibration unit VAS 6350 - Calibration unit VAS 6350
- Spirit level
On calibration unit VAS 6350
For checking horizontal position of calibration unit VAS 6350 - Locating bracket
For mounting spacing laser VAS 6350/2 for distance measurement
Distance to wheel centre mountings VAS 6350/1 on rear wheels: dimension (a) = 1,700 ± 2 mm - Calibration unit for lane change assist VAS 6350/4
Is moved from one side of measuring field to other during calibration
Voltage supply must be connected to bottom left of calibration unit for lane change assist (in direction of travel) - Logo
Laser pointer is aligned with centre of logo - Wheel centre mounting VAS 6350/1
With wheel bolt adapter and measuring paddle - Measuring scale
For positioning the calibration unit for lane change assist VAS 6350/4 - Linear laser VAS 6350/3
With “laser protection goggles”
On calibration unit VAS 6350
Switching on and off Operating instructions for calibration unit VAS 6350 - Plastic foot
3x
Adjustable, for aligning horizontal position of calibration unit VAS 6350
Vehicle must be standing on a smooth and level surface.
On vehicles with air suspension, select “normal level” (MMI setting: comfort or auto).
Apply parking brake – the vehicle must not be moved while the calibration procedure is being performed.
Make sure steering wheel is at centre position with wheels pointing straight ahead.
Connect Vehicle diagnostic tester.
If a fault message appears on the display, refer to Operating instructions for vehicle diagnostic tester.
Switch on ignition.
Remove any stickers with metal film from the bumper cover.
Fit three suitable wheel bolt adapters onto each wheel centre mounting VAS 6350/1.

Fit measuring paddle onto each of the wheel centre mountings VAS 6350/1 and secure each paddle with lock nut.
Fit wheel centre mountings VAS 6350/1 onto wheel bolts on both rear wheels.
Centre of rotation of wheel centre mounting must align with centre of rotation of wheel.When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that the “anti-theft wheel bolts” do not come into contact with the wheel centre mounting.
Use lock nuts to adjust measuring paddles so that they are free to move just slightly above the ground.
Measuring paddles must move freely.Measuring paddle must be in an upright position.Position the calibration unit VAS 6350 at a distance of (a) from rear wheels.

Switch on spacing laser VAS 6350/2 by pressing ON button.

Display on VAS 6350/2:
“- - - m”The laser is switched on simultaneously.To measure distance, hold spacing laser VAS 6350/2(item 2) flush with locating bracket (left-side) as shown in illustration.

Make sure that laser beam for distance measurement hits lower (larger) part of measuring paddle (1).
If this is not the case, adjust height of measuring paddles using lock nuts on wheel centre mountings VAS 6350/1.
Press ON button briefly to measure distance.

Display on VAS 6350/2:
“1.700 m” (specification: 1,700 ± 2 mm).Repeat measurement from locating bracket (right-side) to rear right wheel.
Measured distance value must be identical on both sides.If the two measured values are not identical, re-align calibration unit VAS 6350.
Vehicle diagnostic tester is connected.
Select Diagnosis mode and start this mode.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 3C - Lane change assist control unit - J769
- 3C - Lane change assist control unit, functions
- 3C - Calibration
Start the program selected and follow the instructions on the display of the vehicle diagnostic tester.
The system will now inform you which lane change assist version is fitted in the vehicle (version: SWA 3.0).
This information for setting the calibration unit is important for the work sequence to be followed and to avoid malfunctions.
Secure calibration unit for lane change assist VAS 6350/4 to mounting bracket (rear left) on calibration unit VAS 6350.

Dimension (a) (measured between top edge of calibration unit and ground).
| Model | Q7 basic version | Q7 S line |
|---|---|---|
| Setting dimension in mm Dimension (a) | 681 | 675 |
Pointer at base of calibration unit for lane change assist VAS 6350/4 must align with setting dimension on graduated scale (1) at measuring field (arrow).
| Model | Q7 basic version | Q7 S line |
|---|---|---|
| Setting dimension (left-side) in mm read off from measuring scale (1) | 800 | 817 |
Connect calibration unit for lane change assist VAS 6350/4 up to voltage supply.
Align calibration unit VAS 6350 horizontally by turning plastic feet.

Switch on linear laser VAS 6350/3 on calibration unit VAS 6350.

Put on “laser protection goggles”.
Align calibration unit VAS 6350 so that beam from linear laser VAS 6350/3 hits centre of logo on rear lid.
Again check distance (left and right) between locating brackets of calibration unit VAS 6350 and measuring paddles (1) on wheel mountings.

Please adhere to the following rules during the calibration procedure:
There must not be any metallic reflectors (e.g. tool trolleys, metal cabinets) within 2 metres of the calibration unit.Vehicle doors must not be opened or closed.No-one must sit in vehicle.Do not allow any person to walk between vehicle and calibration unit for lane change assist VAS 6350/4.
Switch on calibration unit for lane change assist VAS 6350/4 with power switch (3).
The green LED (1) must light up.If the red LED (2) lights up: check calibration unit for lane change assist VAS 6350/4.
Continue to follow the instructions on the display of the vehicle diagnostic tester.
During the program, you are prompted to move the calibration unit for lane change assist VAS 6350/4 from the left to the right side of the calibration platform VAS 6350.

Switch off calibration unit for lane change assist VAS 6350/4 and move calibration unit.
Voltage supply must be connected to bottom left of calibration unit for lane change assist (in direction of travel)Dimension (a) (measured between top edge of calibration unit and ground).
| Model | Q7 basic version | Q7 S line |
|---|---|---|
| Setting dimension in mm Dimension (a) | 681 | 675 |
Pointer at base of calibration unit for lane change assist VAS 6350/4 must align with setting dimension on graduated scale (1) at measuring field (arrow).
| Model | Q7 basic version | Q7 S line |
|---|---|---|
| Setting dimension (right-side) in mm read off from measuring scale (1) | 800 | 817 |
Switch on calibration unit for lane change assist VAS 6350/4 with power switch (3).

Continue to follow the instructions on the display of the vehicle diagnostic tester.
After completing calibration of lane change assist, end “Calibration”, switch off ignition and unplug diagnostic connector.
Parts & tools for this job For 2015 Audi Q7
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.