Q7 Quattro V6-3.6L (BHK) (2007)
-
Disconnect condensation water drain hose - A - from condensation water drain of heating A/C unit - D -.
NOTE: Depending on production time period, condensation water drain hose - A - is secured by a hose clamp or a cable tie to condensation water
drain of heating A/C unit - D -.
Installing
-
Secure condensation water drain hose - A - using a hose clamp - B - to condensation water drain of heating A/C unit - D -.
-
When installing heating A/C unit, make sure that condensation water drain is guided into opening - C - of floor plate.
-
Install heating A/C unit and other removed components.
-
Pull condensation water drain hose - A - outward from below through opening in rear floor plate - C -.
-
Secure condensation water drain hose - B - on rear floor plate - C - from below as depicted, make sure that condensation water drain hose is not
twisted when doing this.