audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 7876 > < With Generic Scan Tool|Page 7874
Page 1
background image

Leak Detection Pump: Testing and Inspection
Leak Detection Pump, Checking

Leak Detection Pump, Checking

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› The Leak Detection Pump (V144) fuse OK. 

‹› The ignition switched off.

‹› The voltage for the Leak Detection Pump (-V144-) is supplied by the Secondary Air Injection (AIR) Pump Relay (J299).

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

-

Remove the right rear wheel housing liner.

-

Disconnect the Leak Detection Pump (V144) electrical harness connector - 4 -.

Checking internal resistance

-

Using a Multimeter, check the Leak Detection Pump (V144) for resistance as follows:

With Generic Scan Tool|Page 7876 > < With Generic Scan Tool|Page 7874