Switch off ignition.

-

Connect Test Box V.A.G 1598/42 to wiring harness with adapter lead V.A.G 1598/39-1 or adapter lead V.A.G 1598/39-2. Clamp test box Ground
(GND) clip to battery negative terminal. The procedure will indicate whether the engine control module is to be connected to the test box or not.

CAUTION:
Risk of destroying electrical components with measuring equipment.
-

Before connecting test leads, switch on respective measuring range and observe test conditions.

-

Check the following wire connection for open circuit and short circuit to Ground (GND) and B+:

Harness connector Terminal

V.A.G 1598/42 Bushing

-2-

3.6L: B 8
4.2L: B 10

-

Repair wiring open circuit or short circuit according to wiring diagram.

If no malfunction is found, but leak diagnosis pump is not functional during output diagnostic test mode:

-

Replace Leak Detection Pump (LDP) V144.

-

Observe procedures for after re-connecting engine control module (ECM).