Disconnecting and connecting battery
- Make
- Audi
- Model
- R8 Mk1
- Year
- 2007–2015
- Section
- Battery › Disconnecting and connecting battery
Disconnecting and connecting battery

Press battery cover towards side (arrow A) and lift off (arrow B).
Loosen nut several turns and disconnect battery clamp (arrow) of earth cable from battery terminal.

When connecting battery, attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut.

Unplug electrical connector (2) at battery monitor control unit J367(item 3).
When connecting battery, attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).
Reconnect connector at battery monitor control unit J367.
The following measures are required after re-connecting the battery:
- Activate automatic open/close function of electric window regulators - see Owner's Manual for the vehicle.
- Synchronise spare key and additional key to ensure correct remote control operation. To do so, insert key in ignition lock, switch on the ignition and then off again, then remove the key.
- Interrogate event memories of all control units and erase “Low voltage” entry Vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
Parts & tools for this job For 2007 Audi R8
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
As an Amazon Associate we earn from qualifying purchases.