Disconnecting and connecting battery in engine compartment
- Make
- Audi
- Model
- TT Mk1
- Year
- 1998–2006
- Section
- Battery › Disconnecting and connecting battery in engine compartment
Electrical systemDisconnecting and connecting battery in engine compartment
Disconnecting and connecting battery in engine compartment

Note code (obtain if necessary) for vehicles with coded radio/radio navigation system (RNS).
Switch off ignition and take out ignition key.
Remove cover (front left) (arrows).
Loosen nut several turns and disconnect battery clamp (arrow) of earth cable from battery terminal post.

When connecting battery, attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut.
The following measures must be carried out after re-connecting battery:
- Activate radio/radio navigation system (RNS), clock, automatic open/close function of electric window lifters - see Owner's Manual.
- Interrogate fault memories of all control units and erase “Low voltage” fault display Vehicle diagnosis, testing and information system VAS 5051.
- Additional steps may be required, depending on the type of injection and ignition system Rep. Gr.24.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
| Component | Nm |
|---|---|
| Battery cable clamp to battery terminal | 6 |
Parts & tools for this job For 1998 Audi TT
- PARTEngine gasket setSearch: Audi TT 1998 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.