Checking condensation drain
- Make
- Audi
- Model
- TT Mk2
- Year
- 2006–2014
- Section
- Heater and air conditioning unit › Checking condensation drain
Checking condensation drain
Note
- This vehicle is only fitted with one condensation drain.
- Vehicles with no air conditioner (heater only) are fitted with a plug to seal the opening at the transmission tunnel (no condensation drain is provided).
- There is neither a valve nor a flap at the end of the condensation drain (C).

- In the event of moisture problems in the passenger compartment, check the following in addition to the condensation drain:
Water drains for plenum chamber → Chapter
Plenum chamber cover and cover for fresh air intake duct for correct installation and damage → Chapter
Dust and pollen filter for contamination and correct installation → Chapter
Forced ventilation vents in luggage compartment → Chapter
Actuation and operation of the air flow flap → Chapter and air recirculation flap → Chapter and "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- In the event of problems with moisture in the passenger compartment which only occurs with the air conditioner compressor switched on under certain ambient conditions, additionally check the temperature of the air flowing out of the evaporator as follows "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051:
In the “Reading measured value block” function of the guided fault-finding routine, select the measured value block with the measured value of the evaporator output temperature sender G263.
Check the air outlet temperature at the evaporator under the usage conditions described by the customer or with the following settings on the air conditioner operating unit, Climatronic control unit J255, “Auto” mode, air conditioner compressor switched on (lamp in AC or A/C button lit), “cold” temperature setting, medium fresh air blower speed with a voltage of approx. 7 V at the fresh air blower V2, fresh air mode (lamp in “air recirculation button” not lit) and dash panel vents open.
If the measured value for evaporator output temperature sender G263 is too low (at ambient temperatures above 0 °C, colder than 0 °C for lengthy period) or too high (above e.g. 10 °C although air conditioner is functioning properly), eliminate cause of deviation; observe notes on checking cooling output → Chapter.