Checking cooling output (Heating, air conditioning)
- Make
- Audi
- Model
- TT Mk2
- Year
- 2006–2014
- Section
- Repair instructions › Checking cooling output
Checking cooling output
Test requirements satisfied → Chapter
Special tools, testers and measuring instruments required → Chapter
Measure the ambient temperature (must be above 15 °C).
Close doors, bonnet, windows and rear lid.
Open all dash panel vents.
Switch on ignition.
Start engine.
Set “Econ” mode on the air conditioner operating unit, Climatronic control unit J255 (lamp in AC or A/C button not lit).
Start air conditioner guided fault-finding "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
In the “Reading measured value block” function, select the display group with the measured values for actuation of the air conditioner compressor and for the pressure in the refrigerant circuit and read out the measured values "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Check the measured values shown in the display zones with the values for actuation of the air conditioner compressor regulating valve N280 and for the pressure in the refrigerant circuit.
- The air conditioner compressor is switched off, a current to N280 of 0 A (amps) is displayed.
- At the measured ambient temperature, the pressure in the refrigerant circuit (measured value of high-pressure sender G65) is equal to or higher than the value in the table.
| Ambient temperature in °C | Displayed pressure (in bar absolute) |
|---|---|
| 15 | 4.0 |
| 20 | 5.0 |
| 25 | 6.0 |
| 30 | 7.0 |
| 35 | 8.0 |
Note
- On the absolute pressure scale, 0 bar corresponds to an absolute vacuum. Normal ambient pressure thus corresponds to an absolute pressure of roughly 1 bar. On the scales of most pressure gauges, 0 bar corresponds however to an absolute pressure of one bar (can be seen from -1 mark below 0).
- At present, the measured value block on this vehicle only indicates values as whole numbers. The display fluctuates between two values if the measured pressure is between the two.
- The pressure in the refrigerant circuit is governed by the ambient temperature. Due to the radiation of heat by components (e.g. the radiator), the pressure displayed with a warm engine is slightly higher than that given for the corresponding ambient temperature.
Continuation of test:
- If pressure in refrigerant circuit is OK Anchor.
- If the pressure displayed is lower than that given in the table, check the signal of the high-pressure sender G65Chapter. If no fault is found at the high-pressure sender, there is not enough refrigerant in the circuit. Take the vehicle to a workshop which is equipped with the necessary tools and where the work can be performed by appropriately qualified personnel. Inform the workshop of the problem detected (insufficient refrigerant in circuit) Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
Switch on the air conditioner compressor by selecting “Auto” mode on the air conditioner operating unit, Climatronic control unit J255 (lamp in AUTO button and AC or A/C button light).
Set the rotary temperature control of the air conditioner operating unit, Climatronic control unit J255 to the “cold” stop.
Set the air outflow direction by way of the rotary air distribution control on the air conditioner operating unit, Climatronic control unit J255 to “dash panel vents”.
In the “Reading measured value block” function, select the display group with the measured values for actuation of the air conditioner compressor regulating valve N280 and the measured value of the high-pressure sender G65"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Check the display in the display zones:
- Indication of a duty cycle greater than 30 % (actuation of the air conditioner compressor regulating valve N280, the air conditioner compressor is switched on).
- Indication of a current greater than 0.3 A (current flowing via the air conditioner compressor regulating valve N280, the air conditioner compressor is switched on).
Note
- If the display zone shows no or insufficient current, check actuation of the air conditioner compressor regulating valve N280Chapter.
- The air conditioner compressor regulating valve N280 is actuated by the air conditioner operating unit, Climatronic control unit J255 such that the temperature of the air downstream of the evaporator reaches the specified value (approx. 2 to 5 °C).
- After starting the vehicle, a value greater than 75 % (0.55 A) is displayed depending on the measured temperature, engine speed and electrical system voltage. As soon as the temperature measured by the evaporator output temperature sender G263 approaches the specified value, actuation is cancelled and the compressor output thus reduced.
The displayed pressure in the refrigerant circuit rises above the value with the air conditioner compressor switched off.
Note
- If the pressure displayed does not change and actuation of the air conditioner compressor is OK, check again as to whether the air conditioner compressor is actually being driven. If it is, there is a fault in the refrigerant circuit. Take the vehicle to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems. There may be problems with air conditioner compressor control. Inform the workshop of the problem encountered.
- Under certain operating conditions, residual moisture in the refrigerant circuit may lead to the formation of ice at the air conditioner compressor regulating valve (and at the expansion valve). Such ice formation impedes air conditioner compressor control. The evaporator is excessively cooled and ices up. An iced-up evaporator may cause various problems → Chapter.
Press the air recirculation mode button on the air conditioner operating unit, Climatronic control unit J255 (symbol for “air recirculation mode” in air recirculation button lights).
Set the engine speed to 2000 rpm (start of time measurement).
In the “Reading measured value block” function, select the display with the measured value of the evaporator output temperature sender G263"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
Compare the G263 measured value displayed to the values in the graph.

Depending on the ambient temperature, the measured air temperature must be within the stated tolerance range (C) after 5 minutes.
Note
- If the required values are not attained, check the measured values of the evaporator output temperature sender G263 and the measured value of the front left chest vent temperature sensor G385 (front right chest vent temperature sensor G386 on right-hand drive vehicles) and compare the measured values displayed to one another.
- If the measured value for G263 only differs slightly from the measured value for G385 ( G386): Perform Fault Finding if readout does not match specification → Chapter.
- If the measured value of the evaporator output temperature sender G263 is higher than that of the front left chest vent temperature sensor G385 (front right chest vent temperature sensor G386 on right-hand drive vehicles), check for proper installation of the evaporator output temperature sender G263 and perform the electrical checks for this sender "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- The operation of the air conditioner can be detected e.g. from the fact that the refrigerant pipe on the low-pressure side (thick pipe) cools down.
If the measured value of the evaporator output temperature sender G263 (and the air conditioner cooling output) is OK, continue the testing procedure as follows:
Set the air outflow direction by way of the rotary air distribution control on the air conditioner operating unit, Climatronic control unit J255 to “footwell”.
Compare the measured value displayed for G263 to the measured values of the left footwell vent temperature sender G261 and the right footwell vent temperature sender G262.
After 5 minutes, the measured values for G261 and G262 must not be more than 3 °C higher than that for G263.
Note
- If the required values are not attained, compare the measured values for G261 and G262 to one another.
- If the measured value for one of the two output temperature senders G261 or G262 is OK: Check the activation and operation of the left temperature flap control motor V158 and the right temperature flap control motor V159Chapter, Chapter“Checking heating output, vehicles with air conditioner” and Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- If measured value for G261 and/or G262 is lower than measured value for evaporator output temperature sender G263: Check that G263, G261 and G262 are correctly installed, and check electrical connections for contact resistance; if defective, renew sender Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- If no fault can be determined for the left footwell vent temperature sender G261, the right footwell vent temperature sender G262, the evaporator output temperature sender G263, the left temperature flap control motor V158 or the right temperature flap control motor V159, perform the Fault Finding for cases in which there is a temperature increase downstream of the evaporator → Chapter.
- The temperature of the air flowing out of the “Centre” dash panel vents can also be measured using a commercially available thermometer for example.
- If there are differences in the temperature of the air flowing out of the vents in the same setting (in control mode), there are several possible causes: The temperature flaps in the air distribution housing do not close fully or do not reach the final position Chapter“Air intake and air outlet openings, routing of air flow” and Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051. There is air in the heat exchanger (flow through heat exchanger fluctuates, causing uneven heat distribution) Chapter“Checking heating output, vehicles with air conditioner”. During installation of the heat exchanger, a foam seal became detached, allowing air to flow past the heat exchanger Chapter“Removing and installing heat exchanger”. The air conditioner refrigerant circuit is not filled with the correct amount of refrigerant Air conditioner with refrigerant R134aRep. gr.87Capacities for refrigerant R134a/refrigerant oil and approved refrigerant oils.
The cooling output required is not attained in the cooling output test → Chapter.
| Select the “Reading measured value block” function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.Repeat cooling output test → Chapter.During the cooling output test observe the displays for actuation of the air conditioner compressor regulating valve N280 and the pressure in the refrigerant circuit. N280 deactivated during cooling output test (control current dropped below 0.50 A) ? | ||
| ↓ yes ↓ | ↓ no ↓ | |
| Interrogate the fault memory, eliminate the faults displayed and erase the fault memory. "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. | Increase in pressure in refrigerant circuit (measured value of high-pressure sender G65) during cooling output test? | |
| ↓ | ↓ yes ↓ | ↓ no ↓ |
| Read out the measured value block with the compressor shut-off criteria and eliminate the cause of deactivation "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. | ↓ ContinuationAnchor | Take the vehicle to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems. Inform the workshop of the problems encountered. |
| Repeat the cooling output test. |
| Open bonnet.Repeat cooling output test → Chapter.Read out the measured value block with the display for the pressure in the refrigerant circuit "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.Operation of radiator fan(s) (radiator fan V7 and radiator fan 2 V177) during cooling output test (speed governed by coolant temperature and pressure in refrigerant circuit, determined by engine control unit) or switch-in as soon as pressure in refrigerant circuit exceeds a value of approx. 9 bar? | ||
| ↓ yes ↓ | ↓ no ↓ | |
| Read out the measured value block with the pressure in the refrigerant circuit and actuation of the radiator fans "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.Operation of radiator fan(s) at higher speed as pressure in refrigerant circuit increases? | Check actuation of the radiator fan(s), e.g. in the “final control diagnosis” function. "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.Service the radiator fan actuation system.Repeat cooling output test → Chapter. | |
| ↓ yes ↓ | ↓ no ↓ | |
| Take the vehicle to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems. Inform the workshop of the problems encountered. | Check actuation of the radiator fan(s), e.g. in the “Final control diagnosis” function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.Service the radiator fan actuation system.Repeat cooling output test → Chapter. |
Note
- The pressure in the refrigerant circuit is governed by various factors of influence. As a general rule, however, the pressure should not exceed 20 bar at an ambient temperature of 20 to 25 °C. Under extreme usage conditions (e.g. in hot countries with high ambient temperatures, “stop and go traffic” and high relative humidity), the extremely high cooling output involved may also result in pressures of up to 31 bar.
- At ambient temperatures below 25 °C the pressure in the refrigerant circuit does not usually rise above 16 bar (the radiator fan(s) run(s) and cool(s) the condenser).
- Via the duty cycle (signal from high-pressure sender G65) (display in measured value block) the air conditioner operating unit (Climatronic control unit J255) calculates the pressure in the refrigerant circuit. If the duty cycle is less than 10 % (corresponds to approx. 1.2 bar absolute) or above 78 % (corresponds to approx. 32 bar absolute), the air conditioner operating unit (Climatronic control unit J255) does not switch on the air conditioner compressor (the air conditioner compressor regulating valve N280 is not activated). The air conditioner compressor is only re-activated once the duty cycle exceeds 12 % (corresponding to absolute pressure of 1.8 bar) or drops below 74 % (corresponding to absolute pressure of 29 bar).
- To prevent abrupt air conditioner compressor shut-off on account of excessive pressure in the refrigerant circuit or excessive coolant temperature, the compressor output is reduced by the air conditioner operating unit, Climatronic control unit J255 as soon as the pressure in the refrigerant circuit exceeds 30 bar (absolute) (full compressor output is not released again until the pressure has dropped below 27 bar) or the coolant temperature exceeds 115 °C (complete shutdown at 118 °C).
- If the pressure in the refrigerant circuit has been above 32 bar (duty cycle above 78 %), the air conditioner operating unit (Climatronic control unit J255) does not re-activate the air conditioner compressor until the pressure has dropped below 29 bar (duty cycle less than 74 %).
- For further information on the pressure in the refrigerant circuit, refer to → Chapter (checking pressure signal from high-pressure sender G65) and "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
The cooling output required is attained in the cooling output test, but the air is found to heat up excessively after leaving the evaporator → Chapter
| Use hose clamps up to 40 mm 3093 for example to pinch off the two coolant hoses between the engine and the heat exchanger of the air conditioning unit → Chapter.Repeat cooling output test → Chapter.Read out the measured value block with the measured values for the left footwell vent temperature sender G261, the right footwell vent temperature sender G262 and the evaporator output temperature sender G263"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.The measured values for G261 and G262 differ by less than 3 °C from the measured value for G263"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. | |
| ↓ yes ↓ | ↓ no ↓ |
| Detach the hose clamps up to 40 mm 3093 from the two coolant hoses.↓ | Check the sender supplying the deviating measured value for correct installation, as well as the electrical connections for contact resistance "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. and Current flow diagrams, Electrical fault finding and Fitting locations |
| Check activation and operation of left temperature flap control motor V158 and right temperature flap control motor V159Chapter and → Chapter.↓ | Eliminate cause of incorrect measured value. Renew sender if defective. |
| If actuation and operation of V158 and V159 are OK | |
| ↓ yes ↓ | no ↓ |
| Check operation of the temperature flap for the side of the air distribution housing responsible for the temperature increase → Chapter.If necessary, renew air distribution housing → Chapter.↓Repeat cooling output test → Chapter. | Eliminate the cause of the malfunction "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051 and Current flow diagrams, Electrical fault finding and Fitting locations.↓Repeat cooling output test → Chapter. |
Parts & tools for this job For 2006 Audi TT
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi TT 2006 cabin filter
As an Amazon Associate we earn from qualifying purchases.