01 Technical data for engines02 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)03 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)04 Fuel supply system, petrol engines05 Fuel supply system, diesel engines06 Servicing 7-speed dual clutch gearbox 0AM/0CW07 Rear final drive 0CQ, 0CR08 Servicing 6-speed manual gearbox 02Q, 0BB, 0FB09 6-speed dual clutch gearbox 0D910 6-speed manual gearbox 02Q, 0FB11 6-speed manual gearbox 02S12 7-speed dual clutch gearbox 0CW13 Running gear: Wheel/Tyre Guide14 Brake system15 Running gear, axles, steering16 Heating, air conditioning17 Electrical: Communication18 Electrical system19 General body repairs, exterior20 General body repairs, interior
Audi TT Mk3 (2014-2023)17 · Electrical: Communication
17 · Electrical

Calibrating reversing camera R189

Make
Audi
Model
TT Mk3
Year
2014–2023
Section
Reversing camera system › Calibrating reversing camera R189
Electrical: CommunicationCalibrating reversing camera R189

Calibrating reversing camera R189

Ensure requirements are met Anchor.

Connect Vehicle diagnostic tester.

Fitting wheel centre mountings VAS 6350/1

Check the bolt hole circle pattern on the wheels.

Prepare wheel centre mountings VAS 6350/1 as required.

To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.

Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.

Fit wheel centre mountings VAS 6350/1 onto wheel bolts on rear wheels.

The wheel centre mountings VAS 6350/1 are kept in position by the O-rings in the adapters.

N94-10685

Note

  • When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any “anti-theft” wheel bolts that might be installed.

Use clamping bolts to adjust paddles so that they are free to move just slightly above the ground. Make sure the paddles can move freely.

Set up and align calibration unit VAS 6350Chapter.

Measuring dimension

Switch on spacing laser VAS 6350/2.

The following display will appear.

A91-12101

The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

A91-12100
Position at front edgePosition at rear edge

Hold spacing laser VAS 6350/2(2) flush with bracket on one side of the calibration unit as shown in illustration. Spacing laser VAS 6350/2(2) must make firm contact with bracket.

N94-10684

Briefly press the measurement button.

The laser will switch on.

Laser beam from spacing laser VAS 6350/2(2) must hit lower, larger part of paddle (1).

If this is not the case, position of paddles must be corrected accordingly using clamping bolts on wheel centre mounting VAS 6350/1.

Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350 with one hand while laser beam is visible on paddle.

Now press measurement button briefly to measure distance.

Note down the measured value.

Perform same measuring procedure for rear wheel on other side of calibration unit VAS 6350.

Measured distance value must be identical on both sides.

If values are not identical:

Adjust calibration unit VAS 6350 until values on both sides are identical.

When adjusting, make sure that linear laser VAS 6350/3 hits centre of Audi rings and spirit level display also remains central. Correct if necessary.

Measuring dimension (H)

Measure height of calibration unit VAS 6350: dimension (H) (top edge of platform - floor).

A91-11140

Ensure that spacing laser VAS 6350/2 is correctly adjusted (position at front edge).

The display will show how the spacing laser VAS 6350/2 should be positioned. Press the appropriate key.

A91-12100
Position at front edgePosition at rear edge

Now enter measured distance value and height in millimetres in Vehicle diagnostic tester.

Performing calibration

Vehicle diagnostic tester is connected.

Select Diagnosis mode and start diagnosis.

Select Test plan tab.

Select Own test then the following options one after the other:

  • Body
  • Electrical system
  • 01 - Self-diagnosis compatible systems
  • 6C - Rear-view camera system - J772
  • 6C - Reversing camera system control unit, functions
  • 6C - Calibrate

Further instructions are given by Vehicle diagnostic tester during calibration procedure.

Warning Make sure no light is reflected on calibration platform.
Reflected light impairs the view of the reversing camera R189 and therefore it may be impossible to perform calibration.

Parts & tools for this job For 2014 Audi TT