01 Technical data for engines02 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)03 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)04 Fuel supply system, petrol engines05 Fuel supply system, diesel engines06 Servicing 7-speed dual clutch gearbox 0AM/0CW07 Rear final drive 0CQ, 0CR08 Servicing 6-speed manual gearbox 02Q, 0BB, 0FB09 6-speed dual clutch gearbox 0D910 6-speed manual gearbox 02Q, 0FB11 6-speed manual gearbox 02S12 7-speed dual clutch gearbox 0CW13 Running gear: Wheel/Tyre Guide14 Brake system15 Running gear, axles, steering16 Heating, air conditioning17 Electrical: Communication18 Electrical system19 General body repairs, exterior20 General body repairs, interior
Audi TT Mk3 (2014-2023)18 · Electrical system
18 · Electrical

Disconnecting and connecting battery

Make
Audi
Model
TT Mk3
Year
2014–2023
Section
Battery › Disconnecting and connecting battery
Electrical systemDisconnecting and connecting battery

Disconnecting and connecting battery

Warning Risk of accident.

  • Contrary to the following description, the battery must be disconnected with the ignition SWITCHED ON when working on pyrotechnic components (e.g. airbags, belt tensioners).
Danger of reducing agent escaping on vehicles with SCR system.
  • After the ignition is switched off, the reducing agent is automatically drawn back into the reducing agent tank from the metering line going to the injector for reducing agent N474.
  • Before working in this area, you must therefore wait until the reducing agent has been completely drawn out of the metering line; this can take up to 10 minutes after the ignition has been switched off.
  • For the same reason, it is important to wait until the reducing agent has been drawn back (i.e. 10 minutes) before disconnecting the battery.

Disconnecting

A27-10233

Switch off ignition.

Lift luggage compartment floor using handle and fold forward.

Open cover (3) over negative battery terminal.

Slacken off nut (1) several turns and disconnect battery clamp (2) of earth cable from battery terminal.

Connecting

A27-10252

Unplug electrical connector (2) at battery monitor control unit J367(item 3).

When connecting battery, attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).

Reconnect connector at battery monitor control unit J367.

The following measures are required after re-connecting the battery:

  • Activate automatic open/close function of electric window regulators Owner's Manual for the vehicle.
  • Interrogate event memories of all control units and erase “Low voltage” entry Vehicle diagnostic tester.

Note

  • After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.

Tightening torques

  • Chapter“Exploded view - battery”

Parts & tools for this job For 2014 Audi TT

As an Amazon Associate we earn from qualifying purchases.