01 Technical data for engines02 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)03 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)04 Fuel supply system, petrol engines05 Fuel supply system, diesel engines06 Servicing 7-speed dual clutch gearbox 0AM/0CW07 Rear final drive 0CQ, 0CR08 Servicing 6-speed manual gearbox 02Q, 0BB, 0FB09 6-speed dual clutch gearbox 0D910 6-speed manual gearbox 02Q, 0FB11 6-speed manual gearbox 02S12 7-speed dual clutch gearbox 0CW13 Running gear: Wheel/Tyre Guide14 Brake system15 Running gear, axles, steering16 Heating, air conditioning17 Electrical: Communication18 Electrical system19 General body repairs, exterior20 General body repairs, interior
Audi TT Mk3 (2014-2023)18 · Electrical system
18 · Electrical

Calibrating matrix LED headlights with headlight adjustment unit VAS 5209B

Make
Audi
Model
TT Mk3
Year
2014–2023
Section
Headlights › Calibrating matrix LED headlights with headlight adjustment unit VAS 5209B
Electrical systemCalibrating matrix LED headlights with headlight adjustment unit VAS 5209B

Calibrating matrix LED headlights with headlight adjustment unit VAS 5209B

Note

  • The matrix LED headlights are calibrated with the vehicle diagnostic testerVehicle diagnostic tester.
  • The dipped headlights are adjusted first in this procedure. Afterwards the matrix main beam function is calibrated.

Special tools and workshop equipment requiredHeadlight adjustment unit VAS 5209B
W00-11508

Note

  • The software version of the headlight adjustment unit VAS 5209B must be V 0.80 or above to calibrate the matrix main beam function.

The matrix headlights must be calibrated:

If the position of the headlights has been adjusted (i.e. if they have been removed/installed or if securing bolts have been loosened).If the headlights have been adjusted.If one of the vehicle level senders has been renewed.If the event memory contains the entry “no or incorrect basic setting/adaption”.

Requirements:

Observe requirements for checking and adjusting → Chapter.

Procedure

A94-11597

Align VAS 5209B to centre of vehicle at a distance of (a) = 100 mm Operating instructions of VAS 5209B.

Ensure that VAS 5209B is parallel with transverse axis of vehicle. To do so, adjust laser beam of VAS 5209B so it hits securing bolts for wing at front left and front right (arrows).

A94-11757

Move VAS 5209B in front of left headlight and perform parallel check again.

Warning Danger of dazzling other road users if headlight adjustment unit is not correctly aligned.

  • Take special care to ensure that the headlight adjustment unit is aligned properly. Only after this has been done can you adjust the headlights so that other road users will not be dazzled.

Performing calibration

Vehicle diagnostic tester is connected.

Select Diagnosis mode and start diagnosis.

Select Test plan tab.

Select Own test then the following options one after the other:

  • Body
  • Electrical system
  • 01 - Self-diagnosis compatible systems
  • 55 - Dynamic headlight range control (MxB) -J431
  • 55 - Headlight range control, functions
  • 55 - Basic setting matrix beam (Repair Group 94)

Further instructions are given by Vehicle diagnostic tester during calibration procedure. The dipped headlights must be adjusted first in this procedure → Chapter.

During the program, you will be prompted to determine/read off the angle of the inner edge of the segment in the left headlight in the headlight adjustment unit and to enter this into the tester.

Align light collector lens centrally with reference segment of headlight.

Press the “F1” button (arrow) in the main menu of the VAS 5209B to measure the angle.

A94-11598

Indicated on display:

A94-11599

Press and hold left fog light button (arrow) for at least 3 seconds.

Indicated on display:

A94-11602
Angles of inner reference segment edge are displayed.

Enter angle (arrow) of inner edge of reference segment in vehicle diagnostic tester. If necessary, note "+/-" sign.

Press “F4” button (arrow) on VAS 5209B.

A94-11600

During the program, you will be prompted to determine/read off the angle of the inner edge of the segment in the right headlight in the headlight adjustment unit and to enter this into the tester.

Align VAS 5209B to centre of vehicle at a distance of (a) = 100 mm Operating instructions of VAS 5209 B.

A94-11597

Ensure that VAS 5209 B is parallel with transverse axis of vehicle. To do so, adjust laser beam of VAS 5209 B so it hits securing bolts for wing at front left and front right (arrows).

A94-11757

Move VAS 5209 B in front of right headlight and perform parallel check again.

Align light collector lens centrally with reference segment of headlight.

Press the “F1” button (arrow) in the main menu of the VAS 5209 B to measure the angle.

A94-11598

Indicated on display:

A94-11604

Press and hold right fog light button (arrow) for at least 3 seconds.

Indicated on display:

A94-11602
Angles of inner reference segment edge are displayed.

Enter angle (arrow) of inner edge of reference segment in vehicle diagnostic tester. If necessary, note "+/-" sign.

Press “F4” button (arrow) on VAS 5209 B.

A94-11600

After completing calibration, read out event memory and deal with any faults that are present.