Workshop Manuals Factory service & repair Audi
01 Technical data for engines02 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)03 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)04 Fuel supply system, petrol engines05 Fuel supply system, diesel engines06 Servicing 7-speed dual clutch gearbox 0AM/0CW07 Rear final drive 0CQ, 0CR08 Servicing 6-speed manual gearbox 02Q, 0BB, 0FB09 6-speed dual clutch gearbox 0D910 6-speed manual gearbox 02Q, 0FB11 6-speed manual gearbox 02S12 7-speed dual clutch gearbox 0CW13 Running gear: Wheel/Tyre Guide14 Brake system15 Running gear, axles, steering16 Heating, air conditioning17 Electrical: Communication18 Electrical system19 General body repairs, exterior20 General body repairs, interior
Audi TT Mk3 (2014-2023)18 · Electrical system
18 · Electrical

Calibrating lane change assist

Make
Audi
Model
TT Mk3
Year
2014–2023
Section
Lane change assist › Calibrating lane change assist
Electrical systemCalibrating lane change assist

Calibrating lane change assist

Special tools and workshop equipment requiredCalibration unit VAS 6350
W00-10488

Requirements

The lane change assist control unit J769/ J770 must be calibrated in the following situations:

If lane change assist control unit J769 or lane change assist control unit 2 J770 has been renewed.If the rear bumper cover has been damaged, for instance when parking the car.If the rear bumper cover has been removed and installed.If the event memory contains the entry “no or incorrect basic setting/adaption”.

Test equipment layout

A96-11106
  • Spacing laser VAS 6350/2
    For distance measurement
    For use refer to Operating instructions for calibration unit VAS 6350
  • Calibration unit VAS 6350
  • Spirit level
    On calibration unit VAS 6350
    For checking horizontal position of calibration unit VAS 6350
  • Locating bracket
    For mounting spacing laser VAS 6350/2 for distance measurement
    Distance to wheel centre mountings VAS 6350/1 on rear wheels: dimension (a) = 1,700 ± 2 mm
  • Wheel centre mounting VAS 6350/1
    With wheel bolt adapter and measuring paddle
  • Logo
    Laser pointer is aligned with centre of logo
  • Calibration unit for lane change assist VAS 6350/4
    Is moved from one side of measuring field to other during calibration
    Voltage supply must be connected to bottom left of calibration unit for lane change assist (in direction of travel)
  • Measuring scale
    For positioning the calibration unit for lane change assist VAS 6350/4
  • Linear laser VAS 6350/3
    With “laser protection goggles”
    On calibration unit VAS 6350
    Switching on and off Operating instructions for calibration unit VAS 6350
  • Plastic foot
    3x
    Adjustable, for aligning horizontal position of calibration unit VAS 6350

Preparations

Vehicle must be standing on a smooth and level surface.

Apply parking brake – the vehicle must not be moved while the calibration procedure is being performed.

Make sure steering wheel is at centre position with wheels pointing straight ahead.

Connect Vehicle diagnostic tester.

Note

  • If a fault message appears on the display, refer to Operating instructions for vehicle diagnostic tester.

Switch on ignition.

Remove any stickers with metal film from the bumper cover.

Fit three suitable wheel bolt adapters onto each wheel centre mounting VAS 6350/1.

N94-10685

Fit measuring paddle onto each of the wheel centre mountings VAS 6350/1 and secure each paddle with lock nut.

Fit wheel centre mountings VAS 6350/1 onto wheel bolts on both rear wheels.

Centre of rotation of wheel centre mounting must align with centre of rotation of wheel.

Note

  • When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that the “anti-theft wheel bolts” do not come into contact with the wheel centre mounting.

Use lock nuts to adjust measuring paddles so that they are free to move just slightly above the ground.

Measuring paddles must move freely.Measuring paddle must be in an upright position.

Position the calibration unit VAS 6350 at a distance of (a) from rear wheels.

A96-10286
Dimension (a) = 1,700 mm

Switch on spacing laser VAS 6350/2 by pressing ON button.

N94-10681

Display on VAS 6350/2:

“- - - m”

Note

  • The laser is switched on simultaneously.

To measure distance, hold spacing laser VAS 6350/2(item 2) flush with right locating bracket as shown in illustration.

N94-10684
Spacing laser VAS 6350/2 must be steady and flush with locating bracket.

Make sure that laser beam for distance measurement hits lower (larger) part of measuring paddle (1).

If this is not the case, adjust height of measuring paddles using lock nuts on wheel centre mountings VAS 6350/1.

Press ON button briefly to measure distance.

A96-10289

Display on VAS 6350/2:

“1.700 m” (specification: 1,700 ± 2 mm).

Repeat measurement from locating bracket (left-side) to rear left wheel.

Measured distance value must be identical on both sides.

If the two measured values are not identical, re-align calibration unit VAS 6350.

Performing calibration

Vehicle diagnostic tester is connected.

Select Diagnosis mode and start diagnosis.

Select Test plan tab.

Select Own test then the following options one after the other:

  • Body
  • Electrical system
  • 01 - Self-diagnosis compatible systems
  • 3C - Lane change assist control unit - J769
  • 3C - Lane change assist control unit, functions
  • 3C - Calibration

Further instructions are given by Vehicle diagnostic tester during calibration procedure.

Note

  • The system will now inform you which lane change assist version is fitted in the vehicle (version: SWA 2.0).

Secure calibration unit for lane change assist VAS 6350/4 to mounting bracket (rear right) on calibration unit VAS 6350.

A96-11008
Voltage supply must be connected to bottom left of calibration unit for lane change assist (in direction of travel)

Dimension (a) (measured between top edge of calibration unit and ground).

Setting dimension (height):

Dimension (a) = 769 mm

Pointer at base of calibration unit for lane change assist VAS 6350/4 must align with setting dimension on graduated scale (1) at measuring field (arrow).

Setting dimension (right-side) = 827 mm

Connect calibration unit for lane change assist VAS 6350/4 up to voltage supply.

Align calibration unit VAS 6350 horizontally by turning plastic feet.

N94-10686
Check spirit level on calibration unit VAS 6350(arrow).

Switch on linear laser VAS 6350/3 on calibration unit VAS 6350.

A96-11064

Put on “laser protection goggles”.

Align calibration unit VAS 6350 so that beam from linear laser VAS 6350/3 hits centre of logo on rear lid.

Again check distance (left and right) between locating brackets of calibration unit VAS 6350 and measuring paddles (1) on wheel mountings.

N94-10684
Specification: 1,700 ± 2 mm

Calibration procedure

Please adhere to the following rules during the calibration procedure:

There must not be any metallic reflectors (e.g. tool trolleys, metal cabinets) within 2 metres of the calibration unit.Vehicle doors must not be opened or closed.No-one must sit in vehicle.Do not allow any person to walk between vehicle and calibration unit for lane change assist VAS 6350/4.

Procedure

A96-10358

Switch on calibration unit for lane change assist VAS 6350/4 with power switch (3).

The green LED (1) must light up.

Note

  • If the red LED (2) lights up: check calibration unit for lane change assist VAS 6350/4.

Continue to follow the instructions on the display of the vehicle diagnostic tester.

During the program, you are prompted to move the calibration unit for lane change assist VAS 6350/4 from the right to the left side of the calibration unit VAS 6350.

A96-11007

Switch off calibration unit for lane change assist VAS 6350/4 and move calibration unit.

Voltage supply must be connected to bottom left of calibration unit for lane change assist (in direction of travel)

Setting dimension (height):

Dimension (a) = 769 mm

Pointer at base of calibration unit for lane change assist VAS 6350/4 must align with setting dimension on graduated scale (1) at measuring field (arrow).

Setting dimension (left-side) = 827 mm

Switch on calibration unit for lane change assist VAS 6350/4 with power switch (3).

A96-10358
The green LED (1) must light up.

Continue to follow the instructions on the display of the vehicle diagnostic tester.

After completing calibration of lane change assist, end “Calibration”, switch off ignition and unplug diagnostic connector.

Parts & tools for this job For 2014 Audi TT

As an Amazon Associate we earn from qualifying purchases.