Removing and installing drip rail
- Make
- Audi
- Model
- TT Mk3
- Year
- 2014–2023
- Section
- Air duct system › Removing and installing drip rail
Removing and installing drip rail

Remove plenum chamber cover General body repairs, exteriorRep. gr.50Bulkhead (Exploded view - plenum chamber cover).
If installed: Remove the control unit for structure-borne sound J869(1)Rep. gr.23Senders and sensors (exploded view - actuator and control unit for structure-borne sound) or Rep. gr.24Senders and sensors (exploded view - actuator and control unit for structure-borne sound).
If fitted: Unplug electrical connector (3) from air quality sensor G238.
Remove nuts (arrows).
Detach drip rail (2) from threaded pin (4) and remove from plenum chamber.
Note
- Water can enter the fresh air intake if the drip rail is damaged or not installed properly. This may result in complaints about odour from the heater/air conditioner and/or moisture in the passenger compartment.
- Water can enter the fresh air intake via the drip rail if the plenum chamber cover is damaged or not installed properly.
Install in reverse order.
Tightening torque Fig.“Tightening torque for nuts at drip rail”Parts & tools for this job For 2014 Audi TT