Checking activation of supplementary heater
- Make
- Audi
- Model
- TT Mk3
- Year
- 2014–2023
- Section
- General notes › Checking activation of supplementary heater
Checking activation of supplementary heater
Heat energy is added to the air after it leaves the heat exchanger for the heater (1) via the auxiliary air heater element Z35(2)Vehicle diagnostic tester(“Guided Fault Finding”). However, one condition is that the engine control unit J623 receives a request from the Climatronic control unit J255.

Note
- To protect the battery A on vehicles with a start/stop system, the activation of the auxiliary air heater element Z35 is switched off while the stop function is active. If a request has been received, Z35 is activated again as soon as the engine has been re-started via the start function Vehicle diagnostic tester (“Guided Fault Finding”).
The following conditions must be met for the J255 to transmit a request for activation of the supplementary heater to the engine control unit J623:
The “Automatic supplementary heating” function is not deactivated (indicated on the central display of the dash panel insert (2), adjusted via the multimedia system operating unit E380(1)) Owner's Manual.


Note
- The engine control unit J623 activates the auxiliary air heater element Z35 via the low heat output relay J359 and the high heat output relay J360 so that the load of the alternator C does not exceed 95 %. The next stage is only switched on if the load of the alternator is below 30 ... 77 %, depending on the engine speed Vehicle diagnostic tester (“Guided Fault Finding”) and Current flow diagrams, Electrical fault finding and Fitting locations.
Note
- Activation is switched off as soon as the “Automatic supplementary heating” function is deactivated (indicated on the central display of the dash panel insert (2)), a cut-in criterion in the J255 or engine control unit J623 is no longer met or one of the shut-off criteria is detected.

The J255 cancels the request for activation of the electric supplementary heater under the following conditions:
One of the cut-in criteria is no longer being satisfied.The calculated ambient temperature is greater than approx. 8 °C.The load of the alternator C is above 95 %.Less than 60 % of the air is being routed through the heating system heat exchanger for the left and right side (position of temperature flaps).Stop function of start/stop system active.Parts & tools for this job For 2014 Audi TT