01 Technical data for engines02 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)03 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)04 Fuel supply system, petrol engines05 Fuel supply system, diesel engines06 Servicing 7-speed dual clutch gearbox 0AM/0CW07 Rear final drive 0CQ, 0CR08 Servicing 6-speed manual gearbox 02Q, 0BB, 0FB09 6-speed dual clutch gearbox 0D910 6-speed manual gearbox 02Q, 0FB11 6-speed manual gearbox 02S12 7-speed dual clutch gearbox 0CW13 Running gear: Wheel/Tyre Guide14 Brake system15 Running gear, axles, steering16 Heating, air conditioning17 Electrical: Communication18 Electrical system19 General body repairs, exterior20 General body repairs, interior
Audi TT Mk3 (2014-2023)16 · Heating, air conditioning
16 · Heating & A/C

System overview - refrigerant circuit

Make
Audi
Model
TT Mk3
Year
2014–2023
Section
Refrigerant circuit › System overview - refrigerant circuit
Heating, air conditioningSystem overview - refrigerant circuit

System overview - refrigerant circuit

Air conditioner with refrigerant R134a

HD = High-pressure side

ND = Low-pressure side

A87-11431
  • Air conditioner compressor regulating valve N280
    Checking Vehicle diagnostic tester (“Guided Fault Finding”) and Current flow diagrams, Electrical fault finding and Fitting locationsNoteCertain malfunctions of N280 (e.g. sticking valve or open circuit in coil) can lead to problems with the air conditioner compressor (no cooling output from air conditioner, evaporator icing up etc.). If N280 (and not the air conditioner compressor itself) is the cause of the problem, the air conditioner compressor can be serviced by renewing N280Air conditioner with refrigerant R134aRep. gr.87Renewing components of refrigerant circuit. N280 is not available as replacement part for all air conditioner compressors. If N280 cannot be obtained separately for a particular air conditioner compressor (different versions available), the entire air conditioner compressor must be renewed if problems occur Electronic parts catalogue.
  • Air conditioner compressor
    Exploded view ChapterNoteDepending on the design of the refrigerant line and the production period, the refrigerant line on the low-pressure side may be provided with an additional weight (vibration damper, resonator for reducing noise at refrigerant line) → Chapter. Make sure this component is not in contact with other components and cannot come into contact during operation (noise) Electronic parts catalogue.
  • High-pressure safety valveCautionDanger from escaping pressurised refrigerant if valve is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve.
  • Cap
    With seal
    Always screw on
  • Service connection on low-pressure side
    For measuring and dischargingCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
  • Connection in refrigerant line - low-pressure side
    To air conditioner compressor
  • Connection in refrigerant line - low-pressure side
    From expansion valve
  • Expansion valve
    Exploded view → Chapter
  • Evaporator
    Exploded view → Chapter
  • Connection in refrigerant line - high-pressure side
    To expansion valve
  • Refrigerant line with internal heat exchanger
    In the internal heat exchanger, the hot liquid refrigerant flowing through the high-pressure side gives off energy to the cold refrigerant vapour flowing through the low-pressure side, thus enhancing the efficiency of the air conditioner.
    Removing and installing → Chapter
  • Connection in refrigerant line - high-pressure side
    From condenser
  • Pressure sender for refrigerant circuit G805
    Checking Vehicle diagnostic tester (“Guided Fault Finding”) and Current flow diagrams, Electrical fault finding and Fitting locations
    Removing and installing → Chapter
  • Connection with valve
  • Condenser
    Exploded view → Chapter
  • Desiccant cartridge
    Exploded view → Chapter
  • Service connection on high-pressure side
    For measuring, discharging and chargingCautionDanger from escaping pressurised refrigerant if valve in refrigerant line is defective.Frostbite on skin and other parts of the body.Always discharge refrigerant circuit before removing component; connection has no valve Air conditioner with refrigerant R134aRep. gr.87General notes on air conditioning systems.
  • Cap
    With seal
    Always screw on

Parts & tools for this job For 2014 Audi TT