01 Technical data for engines02 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)03 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)04 Fuel supply system, petrol engines05 Fuel supply system, diesel engines06 Servicing 7-speed dual clutch gearbox 0AM/0CW07 Rear final drive 0CQ, 0CR08 Servicing 6-speed manual gearbox 02Q, 0BB, 0FB09 6-speed dual clutch gearbox 0D910 6-speed manual gearbox 02Q, 0FB11 6-speed manual gearbox 02S12 7-speed dual clutch gearbox 0CW13 Running gear: Wheel/Tyre Guide14 Brake system15 Running gear, axles, steering16 Heating, air conditioning17 Electrical: Communication18 Electrical system19 General body repairs, exterior20 General body repairs, interior
Audi TT Mk3 (2014-2023)16 · Heating, air conditioning
16 · Heating & A/C

Discharging refrigerant circuit (Heating, air conditioning)

Make
Audi
Model
TT Mk3
Year
2014–2023
Section
Repair instructions › Discharging refrigerant circuit
Heating, air conditioningDischarging refrigerant circuit

Discharging refrigerant circuit

Air conditioner with refrigerant R134a

Refrigerant must not be allowed to escape into the environment; it should be extracted from the refrigerant circuit with an air conditioner service station. The extracted refrigerant must then either be re-processed on site or returned to the manufacturer for proper disposal. Different or additional regulations may apply in other countries. For this reason, the vehicle must be taken to a workshop which is equipped with the necessary tools and at which the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (Working with air conditioner service station).

Reason:

If refrigerant R134a escapes into the earth's atmosphere, it contributes towards the greenhouse effect.

Note

  • Refrigerant R134a has far less of a greenhouse effect than R12.
  • Refrigerant R134a does not affect the earth's ozone layer (R134a is an HFC with no chlorine atoms). Depletion of the ozone layer in the upper atmosphere is only brought about by the splitting of carbon-chlorine bonds (as is the case, for example, with refrigerant R12).

After discharging air conditioner, unplug electrical connector from air conditioner compressor regulating valve N280 or from pressure sender for refrigerant circuit G805.

Reason:

The air conditioner compressor regulating valve N280 is then no longer activated and the compressor runs at idle. The air conditioner compressor is designed so that, when running at idle, lubrication of the components of the air conditioner compressor is guaranteed via an internal oil circuit (provided there is enough refrigerant oil in the air conditioner compressor).